IMPORTANT REMARKS
READ THE FOLLOWING REMARKS CAREFULLY AND PAY PARTICULAR ATTENTION TO ALL THE
PARAGRAPHS MARKED WITH THE SYMBOL
COULD COMPROMISE THE CORRECT WORKING ORDER OF THE SYSTEM AND CREATE DANGER
SITUATIONS FOR THE USERS OF THE SYSTEM. KEEP THESE INSTRUCTIONS FOR FUTURE USE.
• These instructions are aimed at professionally qualified "installers of electrical
equipment" and must respect the local standards and regulations in force.
All materials used must be approved and must suit the environment in which
the installation is situated.
• All maintenance operations must be carried out by professionally qualified
technicians. Before carrying out any cleaning or maintenance operations
make sure the power is disconnected at the mains.
• This appliance must be used exclusively for the purpose for which it has
been made. "i.e. for traffic control". The appliance may be used to control
passageways with a maximum width of 3 m.
The unit may be fitted both to the right and to the left of the passageway.
• This product and all its relative components has been designed and manu-
factured by Cardin Elettronica who have verified that the product conforms
in every aspect to the safety standards in force.
IMPORTANT SAFETY INSTRUCTIONS
It is the responsibility of the installer to make sure that the following public safety
conditions are satisfied:
1) Ensure that the boom operating installation is far enough away from the main
road to eliminate possible traffic disruptions.
2) In its vertical movement the boom must not come into contact with overhead
cables and other such obstacles.
3) Manual control switches (including the emergency manoeuvring buttons
EMRG1 and EMRG2) must be installed at a height of between 1,5 and 1,8
m, near enough to the part that is being guided to be within sight of the
operator but far enough away to be safe from the moving components and
in a location not accessible to children. Controls installed externally must
also be protected by a safety device inhibiting unauthorised use.
4) The boom operator is designed for use on passageways through which
vehicles are passing. Pedestrians should use a separate entrance.The boom
must be in full view when it is operating therefore controls must be situated
in a position where the operator can see the boom at all times.
5) At least two warning signs should be placed, where they can be easily seen
by the public, in the area of the system of automatic operation. One inside
the property and one on the public side of the installation.
6) This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction concerning
the use of the appliance by a person responsible for their safety.
7) A correct earth connection is fundamental in order to guarantee the electrical
safety of the machine
8) If you have any questions about the safety of the barrier operating system,
do not install the operator. Contact your dealer for assistance.
TECHNICAL DESCRIPTION
710/ELX3000
Electromechanical barrier with a 24Vdc motor, incorporated electronics, auto-
matic and semiautomatic functions, torque limiter and S449 radio frequency
decoder, optional battery charger and NiMH batteries.
716/EL3024A
Ø 60 mm - 3000 mm long bar complete with bar holder arm with which to
connect it to the barrier
- 24Vdc motor with a steel never ending screw.
- Carter in shock-proof plastic.
- Manual release components in reinforced plastic.
- Geared motor with steel gears in a die cast two-piece aluminium shell.
- Motor support base in zinc-plated steel
- Boom holder in die cast aluminium.
- Lubrication using permanently fluid grease.
- Barrier cabinet in spray painted die cast aluminium.
- Incorporated warning light.
USER INSTRUCTIONS
Attention! Only for EU customers - WEEE marking.
This symbol indicates that once the products life-span has expired
it must be disposed of separately from other rubbish. The user is
therefore obliged to either take the product to a suitable differen-
tial collection site for electronic and electrical goods or to send it
back to the manufacturer if the intention is to replace it with a new
equivalent version of the same product.
Suitable differential collection, environmental friendly treatment and disposal
contributes to avoiding negative effects on the ambient and consequently
health as well as favouring the recycling of materials. Illicitly disposing of this
product by the owner is punishable by law and will be dealt with according to
the laws and standards of the individual member nation.
IMPORTANT REMARKS
. NOT READING THESE IMPORTANT INSTRUCTIONS
During the opening/closing manoeuvre check for correct operation and activate
the emergency stop button in case of danger.
During blackouts the boom can be released and manually manoeuvred (see
manual release pag.18).
Attention! The boom is not balanced and must be held during manual release
Periodically check the correct operation of all safety devices (photoelectric
cells etc.)
Eventual repair work must be carried out by specialised personnel using original
spare parts.
The appliance is suitable for continuous operation (see technical data on page
50).
INSTALLATION INSTRUCTIONS
• The minimum controls which may be installed are OPEN-STOP-CLOSE,
these controls must be installed in a location not accessible to children.
• The ground must be stable enough to firmly hold the plinth and the anchor
plates.
• Where possible protect the barrier cabinet from accidental knocks by passing
vehicles.
• Work out the run of the cables according to the command and control devices
fitted and make sure the system conforms to the local standard and regula-
tions in force (see installation example fig.1 pag. 2).
FITTING THE UNIT
- prepare a cement base with the base plate and anchors "A" embedded.
The cable passage tube "B" and the four threaded bolts "D" M8 must
protrude (30mm) from the base plate.
- the base plate must be perfectly in square, its surface must be clean and
the four threaded bolts must emerge perpendicularly.
Note: the cement base should preferably protrude 50 mm out of the ground
in order to avoid water build up which could damage the appliance.
• To install the barrier proceeds as follows:
- remove the 4 self locking nuts "D" from the four threaded bolts (used to
fasten down the anchors) and insert the base of the barrier "C". Fasten
down the barrier using the 4 self locking nuts and washers "D" supplied
with the appliance.
- it is also possible to fasten the barrier to an already existing cement base
as long as the thickness of the base is great enough to guarantee a strong
hold for the rawlplugs.
We advise you to use the following type of rawlplug: "Steel anchor bolts
M8/diam. 14 for heavy duty use".
OPENING THE ACCESS DOOR (fig.8)
To open the door giving access to the internal components loosen the
two grub screws "E" (situated laterally in the top corners) using a 3 mm
hexagonal key. Open the access door and if necessary pull upwards to
release it from the two plastic hinges "F" located at the bottom.
To close the door, insert the two plastic hinges, located at the bottom,
into the grooves on the access door and when the sides are flush fitting
to the cabinet fasten down the two grub screws "E".
OPENING THE TOP COVER (fig.7)
After having opened and removed the front access panel, loosen the
grub screw "H" and lower the plate "G". Using a posidrive screwdriver
"M" remove the two self-tapping screws "L" and dismantle the top cover.
ASSEMBLING THE BOOM (fig.5)
Work out the orientation of the hub (pos 2, fig.2) depending on which
direction the barrier has to open:
- closing to the left (fig.5A);
- closing to the right (fig.5B);
Fasten down the hub "N" to the bar holder arm using the screw "P".
Insert the hub of the bar holder arm onto the threaded shaft "Q" of the
geared motor, keeping the bar in a vertical position.
Using a rubber mallet make sure the hub is well fastened down and tighten
into place using the screw "J" (M8x35). Fastening torque 30Nm.
17