Alarm Indications - Cardin EL X3000 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

• Set the main operating parameters in the options menu.
• If you have safety devices working with 8.2k contacts select the correct setting from the safety device menu.
TEST
OK
"PROG/OK" to confirm
"PROG/OK" to confirm
T B
F I
TEST
F S
CP
PRESS ANY KEY
"PROG/OK" to confirm
BACK TO TEST MENU
CANCELLATION
"PROG/OK" to confirm
CLEAR ALL MEMORY
"PROG/OK" to confirm
CHANNEL FUNCTION
"PROG/OK" to confirm
"PROG/OK" to confirm
BACK TO RADIO CODES MENU
T B
F I
PROGRAM
Flashing on the display. You have to enter the programming mode to program the system,
F S
CP
T B
F I
OUT OF POS
During normal operation it indicates that the "automatic repositioning" procedure is about to take place. In
F S
CP
this case any commands received (TA, TC, TAL or TD) will automatically start this procedure.
This happens when an N.C. contact is activated (FI, FS, CP) during encoder programming or automatic
T B
F I
STOP PROG
repositioning. Once the passive state of the security devices has been reset the gate will start moving
F S
CP
AUTO PROG
again automatically. It also happens if a blackout occurs during programming.
Safety device test error. Check the condition of the safety devices and make sure that the alarm cuts in
T B
F I
when an obstacle interferes with the beam (the relative LED will switch off). In case of anomalies replace
F S
CP
SAFETY ERR
the damaged safety device or bridge the contact and deactivate the safety test (option menu).
This occurs when the programmer sends a command to the motor and nothing happens (the motor
T B
F I
doesn't move). Check the motor faston connections and the condition of the fuses "F2", "F3" and then
F S
CP
ERROR MOT1
give another opening or closing command. If the motor still doesn't move you are faced with either a
mechanical problem or a problem with the programmer.
T B
F I
If this error occurs during normal motor operation it means that there is a problem with one of the encoder
F S
CP
ERROR ENC1
signals. Check the relative connections and carry out automatic repositioning.
The gate movement direction is different from the encoder setting (eg. the gate moves in the closing
T B
F I
direction while the program is carrying out the opening stage). Check the motor power supply
F S
CP
ERROR DIR1
connections.
T B
F
I
Current sensor error. When the gate is not moving this symbol means there is a problem with the current
F S
C P
ERR. SENS1
sensor.
When the safety edge intervenes the gate will automatically invert for a few moments, both in the closing
T B
F
I
as well as the opening direction, to free the obstacle it will then stop for 3 minutes and then continue
F S
C P
ACT. EDGE
moving in the original direction after a 10 second pre ashing period has elapsed.
When the sensor intervenes the gate will automatically invert for a few moments, both in the closing as
T B
F
I
well as the opening direction, to free the obstacle it will then stop for 3 minutes and then continue moving
F S
C P
ACT. SENS
in the original direction after a 10 second pre ashing period has elapsed.
Language choice:
• Press the right and left buttons simultaneously to enter
• Press the right and left buttons to change the language:
REMOTE
OK
• Press the "PROG/OK" button to confirm the choice.
MEMORISE
OK
MEMORISE [nr ...]
Activation 1
OK
CANCEL [nr ...]
Activation 1
OK
CLEAR ALL MEMORY?
Exit
"PROG/OK" to confIrm
OK
CHANNEL A
COMMAND TD/TAL/TA/TC/
STOP/NO COMMAND
"PROG/OK" to set
EXIT
OK

Alarm indications

the language submenu.
Italiano - English - Français - Deutsch - Español.
PRESS the
MEMORISE [nr ...]
transmitter
channel to be
memorised
PRESS the
CANCEL [nr ...]
transmitter
channel to be
cancelled
CANCELLING.....
OK
CHANNEL B
COMMAND TD/TAL/TA/TC/
STOP/ NO COMMAND
"PROG/OK" to set
CHANNEL D
COMMAND TD/TAL/TA/TC/
STOP/ NO COMMAND
"PROG/OK" to set
21
T B
F S
Press the right and left buttons
simltaneously to enter the
PRESS the
transmitter
channel to be
Activation 2
CODE MEMORISED
memorised
PRESS the
transmitter
channel to be
Activation 2
CODE CANCELLED
cancelled
CHANNEL C
COMMAND TD/TAL/TA/TC/
STOP/ NO COMMAND
"PROG/OK" to set
EXIT
OK
"PROG/OK" to set
BACK TO CHANNEL FUNCTION MENU
Operational indications
Pause time programming or
T B
F I
PAUSE
pause for automatic reclosing
F S
CP
(if activated)
T B
F I
Automatic programming under
way
F S
CP
AUTO PROG
T B
F I
OPENING
Opening stage
F S
CP
T B
F I
STOP OPEN
Block during opening
F S
CP
T B
F I
CLOSING
Closing stage
F S
CP
T B
F I
STOP CLOSE
Block during closing
F S
CP
T B
F I
UPDAT.SNS1
Current sensor updating (only
F S
CP
during programming)
T B
I
TEST
Test mode
F S
C P
T B
F
I
Battery mode with a fully
F S
C P
BATT. [99%]
charged battery
Battery mode with a
T B
F
I
discharged battery. The motor
and commands will be
F S
C P
BATT. [0%]
blocked.
F I
PROGRAM
C P
language submenu
ENGLISH
OK
"PROG/OK" to confirm
MEMORISE [nr ...]
CANCEL [nr ...]

Publicidad

Tabla de contenido
loading