TR 200
After closing the lid, the display (e) shows:
14 days absent
17:53 16.5°C
4217-24.1/G
The regulator immediately regulates to the
temperature set with the control knob
The remaining days until you return are al-
ways displayed. After the set number of days
(at midnight) the regulator automatically termi-
nates economic operation and returns to auto-
matic operation.
If you would like to carry out further alterations
do not yet close the lid.
Please note that the temperature set
Tip
with the control knob
less to your pets, plants, etc. for the entire
course of your absence.
If you intend to return to your house in the
morning, it might be better to start heating
shortly after midnight instead of waiting for
first heating operation in the morning. In this
case, depress the button
set the number of days absent. The display
shows:
. Now you can set the oper-
Automatic +/-
ating mode required on return with the button
"+" (p) or "–" (o), either to continuous heating
operation or to automatic operating mode. If
you have selected continuous heating opera-
tion, the temperature is regulated to the value
set with the control knob
midnight before your return. Do not forget to
depress the button
order to terminate continuous heating opera-
tion.
In case that the holiday operating mode
should be terminated early, it is possible to
either briefly depress the button
or to set the number of days absent to "0" as
described above.
Continuous heating operation for several days
can also be programmed by setting the
number of days as described above and turn-
ing up the economic temperature to the re-
quired value with the control knob
(m)
(m) should be harm-
(q). after having
(k), beginning at
(g) after your return in
(g) twice,
(m).
6.2.6 Control knob set to i
Having the set values displayed
Turn the control knob (n) to the position i. The
upper display line (e) shows the present day.
If the button
(q) is depressed, the follow-
ing group is displayed. Each value in the
group (if entered) is displayed for 5 seconds
before the regulator moves to the next value.
If you wish to have the next value displayed
faster, depress the button (p).
If you wish to have the value displayed for a
longer time, briefly depress the button "–" (o)
and the display keeps showing this parame-
ter.
By depressing the button
moves to the next parameter after 5 seconds.
In the first group, the following general val-
ues are dis-played (e) in a five-second-time,
non-existing values are not considered:
Display example
(5-second-time
sequence)
Temperatures
Room temp. here
21.5 °C
Room temp. remote
21.0 °C
Room temp. set
21.5 °C
(q) the display
Parameter description
Title of the first group
Measured room tempera-
ture at the regulator "here"
is only displayed if an exter-
nal sensor (accessory) is
connected.
Measured room tempera-
ture at the
external sensor (acces-
sory).
The set temperature with
which the regulator is oper-
ating.
39