5. ASSEMBLY AND STARTING

Warning!
You must fully assemble the appliance before
using it for the first time.
5.1 Fitting the wheels (Fig. 4 ÷ 5)
Fit the supplied wheels as shown in figures 4 & 5:
● Fig.4a & 4b: Assembly of wheel kit - version A
● Fig.5a & 5b: Assembly of wheel kit - version B
5.2 Fitting the supporting foot (4)
Fit the supplied rubber stopper as shown in Fig. 6.
5.3 Fitting the air filter (1)
Remove the transportation stop with a screwdriver
or similar and screw the air filter (1) securely to the
equipment. (Fig. 7)
5.4 Replacing the oil sealing plug
(14)
Remove the transportation cover from the oil filler
opening with a screwdriver and insert the supplied
oil dipstick (14) into the oil filler opening (Fig. 8).
5.5 Voltage
The compressor is equipped with a mains cable
with shock-proof plug. This can be connected to any
230V ~ 50Hz shock-proof socket which is protected
by a 16 A fuse. Before you use the machine, make
sure that the mains voltage complies with the speci-
fications on the rating plate. Long supply cables,
extensions, cable reels etc. cause a drop in voltage
and can impede motor start-up. In the case of low
temperatures below +5°C, motor start-up is jeopard-
ized as a result of stiffness.
5.6 On/Off switch (8)
To switch on the compressor, pull out the red knob
(8).
To switch off the compressor, press the red knob (8)
in again (Fig. 2a & 2b).
5.7 Adjusting the pressure (Fig. 1)
● You can adjust the pressure on the pressure
gauge (6) using the pressure regulator (7).
● The set pressure can be taken from the quicklock
coupling (5).
5.8 Setting the pressure switch
The pressure switch is set at the factory.
5.8.1
D 210/8/6 - D 210/8/24 - D 210/8/50
Switch-on pressure:
Switch-off pressure:
5.8.2
D 240/10/24 - D 240/10/50 - D 250/10/24
D 250/10/50 - D 260/10/24 - D 260/10/50
DV2 400/10/24P - DV4 400/10/24P
Switch-on pressure:
Switch-off pressure:

6. CLEANING AND MAINTENANCE

Warning!
Pull the power plug before doing any cleaning
and maintenance work on the appliance.
Warning!
Wait until the compressor has completely cooled
down. Risk of burns!
Warning!
Always depressurize the tank before carrying
out any cleaning and maintenance work.
6.1 Cleaning
● Keep the safety devices free of dirt and dust as
far as possible. Wipe the equipment with a clean
cloth or blow it with compressed air at low pres-
sure.
● We recommend that you clean the appliance im-
mediately after you use it.
● Clean the appliance regularly with a damp cloth
and some soft soap. Do not use cleaning agents
or solvents; these may be aggressive to the plas-
tic parts in the appliance. Ensure that no water
can get into the interior of the appliance.
● You must disconnect the hose and any spraying
tools from the compressor before cleaning. Do
not clean the compressor with water, solvents or
the like.
21
G
B
6 bar
8 bar
8 bar
10 bar

Publicidad