On the top of the cabinet there is a cut out for jumper placement. The default position of the
jumper is the parking position JP1. You have 3 different status led response positions:
- Default, JP on position JP1: Feedback LED active & Status LED not-active/unused
- JP on position JP2: Feedback LED & Status LED both always OFF
- JP cable on position JP2 with voltage supply within range: Feedback LED & Status LED active
(depending on external voltage being present)
- JP on position JP3: Feedback LED active & Status LED always ON (based on power to IRHUB4)
6. Operation
The IR repeater system should now operate each of the controlled components. When the
system is operating correctly, you should see a Blue "talk-back" LED flash on the front of the
IRLPRO Flush IR Receiver when you aim your hand held remote control(s) at it and press the
buttons.
7. How to avoid and solve possible problems
Although the ebode IR Link Pro Flush is equipped with proprietary eIR
Technology, which guarantees a high level of immunity of InfraRed noise from direct sunlight, CFL
lighting and Flat Panel TV's (including Plasma, LCD and LED), in rare cases, the IRLPRO Flush IR
Receiver may have to be moved to a different location if the unit is picking up unexpected
interference. This interference may, in severe cases, prevent the system from working.
After repositioning, check to see if the IR Link Pro Flush operates the satellite Receiver or other
components. If the IR Link Pro Flush still does not work, reposition the IRED Emitter(s). It may not be
located directly over the component's InfraRed receiving "window". Consult the owner's manual
of the unit or the manufacturer for the exact location of the InfraRed "window".
IMPORTANT: For installations involving more than two remote rooms, use the services of a
competent professional audio/video installer experienced in InfraRed remote control systems.
Do you still have questions? Please refer to
8. Technical information
IRLPRO FLUSH IR RECEIVER SPECIFICATIONS
•
InfraRed modulation frequency bandwidth: 30 - 60 kHz.
•
Cable length 2m, extendable to max. 300 metres (UTP or equivalent).
•
Red 3.5mm TRRS plug pin configuration from tip to sleeve:
Tip = yellow = IR Data
o
Ring 1 = black = Ground = Thin wire 3
o
Ring 2 = red = +12VDC = Thin wire 4 outside, opposite end to yellow/white striped
o
Sleeve = white = Status = Thin wire 2 next to yellow/white striped
o
•
Reception range: Up to 10 meters, depending on local conditions and remote control used.
•
Reception angle: 45 degrees off axis.
•
Talkback LED (BLUE). Indicates InfraRed reception only when Emitter(s) are connected.
•
Status LED (AMBER). Indicates power status of A/V system
•
Maximum number of directly driven IRED IR Emitters: 4 triple Emitters using the IRHUB4
Connecting Hub. Up to six IRLPRO Flush IR Receivers may be connected in parallel at the
screw terminals input of IR Link IRHUB series connecting blocks (e.g. optional IRHUB2CI and
IRHUB4). Power requirements: 12 volts DC @ 25 mA. Requires 12VDC Power Supply (included).
•
Dimensions IRLPRO Flush IR Receiver: 50 mm x Ø 12 mm