Mount The Keypad - Tyco DSC PowerSeries neo HS2ICONX Serie Instrucciones De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Introduction
The HS2LED/HS2ICN(P)(RF)x/HS2LCD(RF)(P)x keypads are compatible
with the PowerSeries Neo HS2016/32/64, HS2016-4* and HS2128 panels.
The RF keypads combine a wireless transceiver with the respective HS2
keypad.
*Model not UL/ULC listed.
Specifications
Temperature range: -10°C to +55°C (14°F to 131°F); UL/ULC: 0°C
l
to +49°C (32°F to 120°F)
Humidity (MAX): 93%R.H. non-condensing
l
Plastic enclosure protection degree: IP30, IK04
l
Voltage rating: 13.8Vdc nominal (power provided by the compatible
l
control panel)
Connects to control panel Corbus via 4 wires
l
1 configurable zone input or PGM output*
l
HS2LED/ HS2ICN(P)/HS2LCD(P)/HS2ICNRF(P)/HS2LCDRF(P)
l
Current draw:55mA(min)/105mA(max)
Wall-mount tamper
l
5 programmable function keys
l
Ready (Green LED), Armed (Red LED), Trouble (Yellow LED),
l
AC (Green LED)
Dimensions (L x W x D): 168mm x 122mm x 20 mm
l
Weight: 260g
l
Low temperature sensor
l
Frequency: 433 MHz (HS2ICNRF4/HS2LCDRF4)
l
868 MHz (HS2ICNRF8/HS2LCDRF8)
l
912-919MHz (HS2ICNRF9/HS2LCDRF9)
l
Up to 128 wireless zones
l
Zone not to be programmed as Fire type or 24h type.
NOTE: Keypads contain no serviceable parts.
NOTE: Only models operating in band 912-919MHz are UL/ULC listed.
Unpack
The keypad package includes the following:
HS2LED/ICN(RF)/LCD(RF) HS2ICN(RF)P/LCD(RF)P
1 keypad
1 keypad
4 mounting screws
4 mounting screws
2 end-of-line resistors
2 end-of-line resistors
Keypad inner door labels
Keypad inner door labels
1 tamper switch
1 tamper switch
Installation Instructions
Installation Instructions
Mini Proximity (prox) tag (MPT)
Table 1: Compatible Devices
Wireless PG smoke detector
Wireless PG smoke and heat detector
Wireless PG CO detector
Wireless PG PIR motion detector
Wireless PG PIR + camera motion detector
Wireless PG curtain motion detector
Wireless PG dual tech motion detector
Wireless PG mirror motion detector
Wireless PG outdoor motion detector
Wireless PG glass break detector
Wireless PG shock detector
Wireless PG flood detector
Wireless PG temperature detector (indoor)
Outdoor temperature probe (requires PGx905)
Wireless PG key
Wireless PG key
Wireless PG panic key
Wireless PG 2-button key
Wireless PG indoor siren
Wireless PG outdoor siren
Wireless PG repeater
Wireless PG door/window contact
Wireless PG door/window contact w/AUX
NOTE: In this chart, x in the model number represents the operating fre-
quency of the device as follows: 9 (912-919 MHz), 8 (868MHz), 4
(433MHz).
NOTE: Only models operating in the band 912-919 MHz are UL/ULC or
cUL listed where indicated. Only UL approved devices are to be used
with UL/ULC listed systems.

Mount the Keypad

Mount the keypad where it is accessible from designated points of entry
and exit. Once a dry and secure location has been selected, perform the fol-
lowing steps to mount the keypad.
Disassemble Keypad
Insert the tip of a flat-head screwdriver into the slots at the bottom left
and right of the keypad.
Gently pry open the faceplate. This will remove it and allow access for
mounting.
PGx926UL
Mount and Wire Keypad
PGx916UL
PGx913
PGx904(P)UL
PGx934(P)UL
PGx924UL
PGx984(P)
PGx974(P)UL
PGx994UL
PGx912/PGX922 UL
PGx935UL
PGx985UL
PGx905UL
PGTEMP-PROBE
PGx939UL
PGx929UL
PGx938UL
1. Secure keypad to wall using mounting holes. Use all four screws
PGx949UL
provided unless mounting on a single gang box. Use the plastic anchors
PGx901UL
supplied if the unit is to be mounted on drywall.
PGx911UL
2. If using the keypad tamper, secure the tamper plate to the wall with a
PGx920UL
screw.
PGx975UL
NOTE: For UL/ULC listed commercial burglary installations, the use of
PGx945UL
the keypad tamper is mandatory.
3. Run wire through wiring slot or knockouts. Connect Corbus and
PGM/Zone wiring to keypad. Place tamper switch into tamper hole on
backplate.
4. Place keypad into backplate, ensuring the wire is pushed back into the
wall as much as possible. Route the wire inside the keypad, ensuring high
components are avoided. Snap the front assembly closed, ensuring that