Kohler K-6228 Manual Del Usuario página 8

Ocultar thumbs Ver también para K-6228:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

5. Adjust the Valve - Right Handle
CAUTION: Risk of property damage. The water supply
must be shut off before performing these steps.
CAUTION: Risk of property damage. At the maximum
valve body extension, a detent will be encountered. To avoid
leakage, do not extend the valve beyond this detent. If the
valve needs to be extended further, install deep rough-in kit
1107027. If the valve needs to be recessed further, install
shallow rough-in kit 1107026.
Shut off the water supply.
Remove the plaster guard/retaining ring tool.
Position a bucket at the spout outlet, then open the valve handle
to relieve water pressure. Leave the handle open.
Using the tool, loosen the threaded retaining ring until the valve
body disengages from the mixer valve.
Using a straight edge, adjust and hold the valve body flush with
the finished wall.
NOTE: A screwdriver inserted through the holes in the plaster
guard/retaining ring tool can serve as a handle.
With the valve body flush with the finished wall, retighten the
retaining ring with the tool.
Close the valve handle.
Turn on the water supply and check that the valve is functioning
properly.
1095311-2-J
Retaining Ring
Plaster Guard/
Retaining Ring Tool
8
Kohler Co.

Publicidad

Tabla de contenido
loading

Tabla de contenido