Control input operating logic:
Dip 5
OFF
OFF
OFF
OFF
ON
ON
ON
ON
Logic description:
Condominium plus: when the gate is closed the APCH command controls opening, during the opening phase it is ignored. Once opening has completed
the gate is paused for the rest time. During the pause time an APCH command makes the automatic closing time restart from zero. During closing the APCH
command controls reopening.
Automatic: when the gate is closed the APCH command controls opening, during the opening phase it stops the gate and with an additional command the
gate closes. If it completes opening, the gate is paused for the rest time. During the pause time an APCH command makes the gate restart with closing.
During closing the APCH command controls reopening.
Condominium: with the gate closed an APCH input command controls opening, during gate opening the APCH command is ignored by the control unit, with
the gate fully open it stays open for the automatic closing time. With an APCH command during the pause the gate starts to close, an additional command
during closing controls reopening.
Semi-automatic: with the gate closed an APCH input command controls opening. During opening the APCH command stops the gate. When the gate is
fully open and automatic closing is not active, to close the gate before the automatic closing time you need to apply a command via the APCH input, another
APCH command during closing controls reopening.
Step-by-step: with the gate closed an APCH input command controls opening. During opening the APCH command stops the gate. When the gate is fully
open, automatic closing is not active, to close the gate you need to apply a command via the APCH input, another APCH command during closing stops the
gate and another pulse causes reopening.
Close immediately: engaging the photocells causes the gate to close 5 seconds after they are disengaged, regardless of the set rest time.
24
Dip 6
Dip 7
OFF
OFF
OFF
ON
ON
OFF
ON
ON
ON
OFF
ON
ON
OFF
OFF
OFF
ON
Logic
Condominium plus
Condominium plus+ close immediately
Automatic
Automatic+ close immediately
condominium
Condominium + close immediately
Semi-automatic
Step-by-step
EN