10-Troubleshooting:

Problem
The automatic gate system does not work
You cannot save the remote controls
The remote control does not work
You cannot enter travel programming
As soon as the gate starts it stops
During slowdown, the gate stops
EN
Cause
No mains supply
Blown fuses
Control and safety inputs not working
Safety devices open
Batteries of the remote control discharged
Remote control not compatible with the first one
saved
Reached memory saturation
Batteries of the remote control discharged
Safety devices open
Motor power not enough
Slowdown speed too low
Solution
Check the power line switch
Replace the fuses with others of the same value
Check the diagnosis leds (STOP, STPA and PHOTO
must be on)
Check the diagnosis leds (STOP, STPA and PHOTO
must be on)
Replace the batteries
The first saved remote control configures the control
panel to save only rolling-code remote controls or only
dip-switch remote controls
Delete at least one remote control or add an external
receiver (maximum capacity 128 remote controls)
Replace the batteries
Check the diagnosis leds (STOP, STPA and PHOTO
must be on)
Increase the FORCE M1 and FORCE M2 trimmer
Increase the TR4 slowdown speed trimmer