BEFORE INSTALLING:
1.
All installations should comply with National and local electrical codes. If you
have any doubts concerning installation contact a qualified, licensed electrician.
2.
This fixture can only be used with Kichler Cabinet Lighting fixtures and
accessories.
3.
This fixture must be installed using interconnect cables 10571 (9"), 10572 (14"),
10573 (21"), connected to wire module 10570 or existing Kichler Cabinet
Lighting fixture and can also be installed by directly connecting to another
Kichler Cabinet Lighting fixture.
4.
Mounting surface should be a minimum of ½" thick.
5.
When using interconnect cables or connecting fixture to fixture, fixtures can
have a maximum of 3 units in a single run.
Model
Voltage
Number
4U12X08_ _ _
120V
4U12X12_ _ _
120V
4U12X22_ _ _
120V
4U12X30_ _ _
120V
INSTALLATION INSTRUCTIONS USING LINE CONNECTION
1.
Turn off power.
2.
Open wiring compartment by inserting flat-head screwdriver into the slots
and wedging cover open. (ref. FIG. 1)
3.
Remove knock-out that allows for easiest access to conduit. Knock-out
should be removed by inserting flat-headed screwdriver into the knock-out
slot and rocking up and down until knock-out releases. (ref. FIG. 2)
4.
Install conduit connector in knock-out hole on fixture housing.
5.
Run wire through installed conduit connector ensuring that at least 3" of wire
extend into the wiring compartment. The provided conduit connector may
only be used with the following:
• 14/2 to 10/2 steel armored cable;
• 3/8" trade sized reduced wall flexible steel or aluminum conduit;
or
• 14/2 to 10/2 non-metallic sheathed cable
6.
Tighten screws on conduit connector to clamp wire into place.
7.
Hold the fixture in the desired mounting location and drive mounting screws
into cabinet surface until fixture is secure. If screws are difficult to install,
mark holes and drill 1/16" maximum pilot holes. (ref. FIG. 3)
8.
Make grounding connection (connector provided).
9.
Make wire connections (connectors provided).
Connect Black or
Red Supply Wire to:
Black
*Parallel cord (round & smooth)
Clear, Brown, Gold or Black
without tracer
Insulated wire (other than green)
with copper conductor
*Note: When parallel wires (SPT I & SPT II)
are used. The neutral wire is square shaped
or ridged and the other wire will be round in
shape or smooth (see illus.)
10. Open glass diffuser by pressing on tab of each diffuser end cap. Lift and
slide diffuser towards rear of fixture. Remove protective sleeve(s) from bulb(s).
11. Close glass diffuser by swinging edge with tabs up towards fixtures until
pegs by tabs slip into slots at the front of the fixture end caps. Slide tabs
forward, allowing pegs to seat in slots. Lens should be level and flush with
fixture.
12. Swing the cover towards the fixture and close it by pressing at the ends of
the cover until the cover snaps into place and is flush with the fixture.
CAUTION: Ensure that the wires are not pinched or damaged by any part of
the metal housing or clips.
NOTE: See Step 2 to re-access wiring compartment.
13. Place connector cover over any connector not being used. (ref. FIG. 4)
14. Turn on power.
See Page 2 for:
• Installation Instructions using Plug-In Cord
• Installation Instructions using Interconnect Cable
• Installation Instructions for Fixture to Fixture
• Installation Instructions for Replacing Lamps
• Installation Instructions for Replacing Power Supply
Date Issued: 12/4/15
Kichler® Xenon Under-Cabinet
Power Supply
Wattage
Model
18W
4UT12V30
36W
4UT12V60
54W
4UT12V60
72W
4UT12V72
Connect
White Supply Wire to:
White
*Parallel cord (square & ridged)
Clear, Brown, Gold or Black
with tracer
Insulated wire (other than green)
with silver conductor
Neutral Wire
4U SERIES, CP301174
4U12X_ _ _ _ _
NOTE:
Read all instructions thoroughly before starting installation.
CAUTION:
To reduce the risk of fire, electric shock, or injury to persons:
a)
Use only insulated staples or plastic ties to secure cords;
b)
Route and secure cords so that they will not be pinched or damaged when
the fixture is pushed to the wall;
c)
Not intended for recessed installation in ceiling, or soffits;
d)
Not intended for surface installation inside built-in furnishings such as kitchen
cabinets, china cabinets, or trophy cases;
e)
The National Electric Code (NEC) does not permit cords to be concealed
where damage to insulation may go unnoticed. To prevent fire danger, do not
run cord behind walls, ceilings, soffits, or cabinets where it may be inaccessible
for examination. Cords should be visually examined periodically and immediately
replaced when any damage is noted.
FIG. 1
FIG. 3
MOUNTING SCREW
We're here to help
FIG. 2
KNOCK-OUT
MOUNTING SCREW
22" & 30"
MODELS ONLY
FIG. 4
866-558-5706
Hrs: M-F 9am to 5pm EST
KNOCK-OUT
CONDUIT
CONNECTOR
Page 1
IS-4U12X-US_English

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Kichler 4U Serie

  • Página 1 Use only insulated staples or plastic ties to secure cords; This fixture can only be used with Kichler Cabinet Lighting fixtures and Route and secure cords so that they will not be pinched or damaged when accessories.
  • Página 2 Once installed, swing the cover towards the fixture and close it by pressing at the ends of the cover until the cover snaps into place and is flush with the fixture. Connect fixture to existing Kichler Cabinet Lighting system using interconnect cable. Hold interconnect cable to mounting surface and determine best path for cable.
  • Página 3: Before Installing

    Pour L’assemblage et L’installation Au Canada This fixture can only be used with Kichler Cabinet Lighting fixtures and accessories. This fixture must be installed using interconnect cables 10571 (9”), 10572 (14”), 10573 (21”), connected to wire module 10570 or existing Kichler Cabinet...
  • Página 4 Once installed, swing the cover towards the fixture and close it by pressing at the ends of the cover until the cover snaps into place and is flush with the fixture. Connect fixture to existing Kichler Cabinet Lighting system using interconnect cable. Hold interconnect cable to mounting surface and determine best path for cable.
  • Página 5: Avant De Procéder À L'installation

    10572 (14 po), 10573 (21 po), connectés au module de câblage 10570 ou au luminaire d’éclairage pour armoire Kichler existant et peut également être ATTENTION: Pour réduire le risque d’incendie, de choc électrique ou de installé en le connectant directement à un autre luminaire d’éclairage pour blessure: armoire Kichler.
  • Página 6 Connecter le luminaire à un système d’éclairage Kichler pour armoire avec un câble d’interconnexion.
  • Página 7: Antes De Instalar

    10571 (9”), 10572 (14”), 10573 (21”), conectados al módulo de cables 10570 o No está diseñado para instalación empotrada en el techo o plafones; al artefacto existente de iluminación de gabinetes de Kichler, y también No está diseñado para instalación superficial en el interior de mobiliario puede ser instalado mediante conexión directa con otro artefacto de iluminación...
  • Página 8 Conecte el artefacto al sistema existente de iluminación de gabinetes de Kichler utilizando el cable de interconexión. Sostenga el cable de interconexión sobre la superficie de montaje y determine la mejor ruta para el cable.

Este manual también es adecuado para:

4u12x08 serie4u12x12 serie4u12x22 serie4u12x30 serie

Tabla de contenido