BEFORE INSTALLING:
1.
All installations should comply with National and local electrical codes. If you
have any doubts concerning installation contact a qualified, licensed electrician.
2.
This fixture can only be used with Kichler Cabinet Lighting fixtures and
accessories.
3.
This fixture must be installed using interconnect cables 10571 (9"), 10572 (14"),
10573 (21"), connected to wire module 10570 or existing Kichler Cabinet
Lighting fixture and can also be installed by directly connecting to another
Kichler Cabinet Lighting fixture.
4.
Mounting surface should be a minimum of ½" thick.
5.
When using interconnect cables or connecting fixture to fixture, fixtures can
have a maximum of 3 units in a single run.
Model
Number
4U120X08_ _ _
4U120X12_ _ _
4U120X22_ _ _
4U120X30_ _ _
INSTALLATION INSTRUCTIONS USING LINE CONNECTION
1.
Turn off power.
2.
Open wiring compartment by inserting flathead screwdriver into the slots and
wedging cover open. (ref. FIG. 1)
3.
Remove knock-out that allows for easiest access to conduit. Knock-out
should be removed by inserting flat-headed screwdriver into the knock-out
slot and rocking up and down until knock-out releases. (ref. FIG. 2)
4.
Install conduit connector in knock-out hole on fixture housing.
5.
Run wire through installed conduit connector ensuring that at least 3" of wire
extend into the wiring compartment. The provided conduit connector may
only be used with the following:
• 14/2 to 10/2 steel armored cable;
• 3/8" trade sized reduced wall flexible steel or aluminum conduit;
or
• 14/2 to 10/2 non-metallic sheathed cable
6.
Tighten screws on conduit connector to clamp wire into place.
7.
Hold the fixture in the desired mounting location and drive mounting screws
into cabinet surface until fixture is secure. If screws are difficult to install,
mark holes and drill 1/16" maximum pilot holes. (ref. FIG. 3)
8.
Make grounding connection using supplied wire nut found in parts bag.
9.
Make wire connections (connectors provided).
Connect Black or
Red Supply Wire to:
Black
*Parallel cord (round & smooth)
Clear, Brown, Gold or Black
without tracer
Insulated wire (other than green)
with copper conductor
*Note: When parallel wires (SPT I & SPT II)
are used. The neutral wire is square shaped
or ridged and the other wire will be round in
shape or smooth (see illus.)
10. Open glass diffuser by pressing on tab of each diffuser end cap. Lift and slide
diffuser towards rear of fixture. Remove protective sleeve(s) from bulb(s).
11. Close glass diffuser by swinging edge with tabs up towards fixtures until
pegs by tabs slip into slots at the front of the fixture end caps. Slide tabs
forward, allowing pegs to seat in slots. Lens should be level and flush with
fixture.
12. Swing the cover towards the fixture and close it by pressing at the ends of
the cover until the cover snaps into place and is flush with the fixture.
CAUTION: Ensure that the wires are not pinched or damaged by any part of
the metal housing or clips.
NOTE: See Step 2 to re-access wiring compartment.
13. Place connector cover over any connector not being used. (ref. FIG. 4
14. Turn on power.
See Page 2 for:
• Installation Instructions using Plug-In Cord
• Installation Instructions using Interconnect Cable
• Installation Instructions for Fixture to Fixture
• Installation Instructions for Replacing Lamps
Date Issued: 12/4/15
Kichler
Voltage
Wattage
120V
20W
120V
40W
120V
60W
120V
80W
Connect
White Supply Wire to:
White
*Parallel cord (square & ridged)
Clear, Brown, Gold or Black
with tracer
Insulated wire (other than green)
with silver conductor
Neutral Wire
Xenon Under-Cabinet
®
4U SERIES, CP301173
4U120X_ _ _ _ _
NOTE:
Read all instructions thoroughly before starting installation.
CAUTION:
To reduce the risk of fire, electric shock, or injury to persons:
a)
Use only insulated staples or plastic ties to secure cords;
b)
Route and secure cords so that they will not be pinched or damaged when
the fixture is pushed to the wall;
c)
Not intended for recessed installation in ceiling, or soffits;
d)
Not intended for surface installation inside built-in furnishings such as kitchen
cabinets, china cabinets, or trophy cases;
e)
The National Electric Code (NEC) does not permit cords to be concealed
where damage to insulation may go unnoticed. To prevent fire danger, do not
run cord behind walls, ceilings, soffits, or cabinets where it may be inaccessible
for examination. Cords should be visually examined periodically and immediately
replaced when any damage is noted.
FIG. 1
FIG. 3
MOUNTING SCREW
We're here to help
FIG. 2
KNOCK-OUT
MOUNTING SCREW
22" & 30"
MODELS ONLY
FIG. 4
866-558-5706
Hrs: M-F 9am to 5pm EST
KNOCK-OUT
CONDUIT
CONNECTOR
Page 1
IS-4U120X-US_English