Husky Y6020 Manual Del Operador página 17

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

PROBLEM
Pressure reading
on the regulated
pressure gauge
drops when an
accessory is
used.
Compressor is
not supplying
enough air to
operate
accessories.
Regulator knob
has continuous
air leak.
Regulator will
not shut off air
outlet.
CAUSE
It is normal for "some"
pressure drop to occur.
Prolonged excessive use of
air.
Compressor is not large
enough for air requirement.
Hole in hose.
Check valve restricted.
Air leaks.
Damaged regulator
Damaged regulator
If there is an excessive
amount of pressure drop
when the accessory is used,
adjust the regulator following
the instructions in the
"Description of Operation"
paragraph in the "Operation
Section.
NOTE: Adjust the regulated
pressure under flow
conditions (while accessory
is being used).
Decrease amount of air
usage.
Check the accessory air
requirement. If it is higher
than the SCFM or pressure
supplied by your air
compressor, you need a
larger compressor.
Check and replace if
required.
Remove and clean, or
replace.
Tighten fittings.
Have checked by a Trained
Service Technician.
Have checked by a Trained
Service Technician.
17- ENG
CORRECTION
D29616

Publicidad

Tabla de contenido
loading

Tabla de contenido