Protecting The Environment; General Notes; Exhaust Air Mode; Ventilation Line - Bosch HUI54452UC Instrucciones De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Protecting the environment

Unpack the appliance and dispose of the packaging in
an environmentally friendly manner.

General Notes

Exhaust air mode

Note: Ventilation may not exit through an already
operational smoke or exhaust chimney, nor a duct used
for ventilating furnace installation areas.
If the ventilation is intended to pass through a smoke
or exhaust chimney that is not in operation, the
responsible area heating inspector must give
approval.
If the ventilation passes through an external wall, use a
telescopic wall sleeve.

Ventilation line

Note: The appliance manufacturer is not responsible for
and does not warant for complaints attributable to the
pipe section.
The appliance achieves its optimum performance by
means of a short, straight exhaust air pipe and as
large a pipe diameter as possible.
As a result of long rough exhaust air pipes, many pipe
bends or pipe diameters that are smaller than 6"
(150 mm), the optimum extraction performance is not
achieved and fan noise is increased.
The pipes or hoses for laying the exhaust air line must
consist of non-combustible material.
Round pipes
An inner diameter of 6" (150 mm), but at least 4
(120 mm), is recommended.
Flat ducts
The inner cross-section must correspond to the diameter
of the round pipes.
dia. 6" (150 mm) approx. 27
dia. 4
_
" (120 mm) approx. 26
Flat ducts should have no sharp deflections.
Use sealing strip for deviating pipe diameters.
10
G e n e r a l N o t e s
_
)
^
sq in (177 cm
2
_
sq in (113 cm
)
2

Electrical connection

WARNING
9
RISK OF ELECTRIC SHOCK
Parts inside the appliance can have sharp edges.
The connection cable can be damaged. Do not
bend or pinch connection cables during installation.
Check your domestic installation before installing the
appliance. Pay attention to suitable fusing of your
domestic installation. The voltage and frequency of the
appliance must agree with the electrical installation (see
rating plate).
The appliance complies with protective class I and may
only be operated with a PE conductor connection.
The installation must contain a disconnector with a
contact opening of at least
poles from the mains. It must still be accessible after
installation.
Only an electrical specialist may lay or replace the
connecting lead, paying attention to the applicable
regulations.
If the mains connecting lead of this appliance is
damaged, it must be replaced with a special connecting
lead, which is obtainable from the manufacturer or the
manufacturer's after-sales service.
"
" (3 mm) that isolates all