Meter Description; Display Icons Description - koban KPA-1000 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

KPA-1000
Reorient or relocate the receiving antenna Increase the separation between the equipment
and receiver
Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected
Consult the dealer or an experienced radio/TV technician for help.
CAUTIONS
• Improper use of this meter can cause damage, shock, injury or death. Read and
understand this user manual before operating the meter.
• Always remove the test leads before replacing the battery .
• If the test leads need to be replaced, you must use a new one which should meet EN
61010-031 standard.
• Inspect the condition of the test leads and the meter itself for any damage before
operating the meter. Repair or replace any damage before use.
• Use great care when making measurements if the voltages are greater than 25VAC rms
or 35VDC. These voltages are considered a shock hazard.
• Always discharge capacitors and remove power from the device under test before
performing Diode, Resistance or Continuity tests.
• Voltage checks on electrical outlets can be difficult and misleading because of the
uncertainty of connection to the recessed electrical contacts. Other means should be
used to ensure that the terminals are not "live".
• If the equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.
Function
A AC, A DC
V DC, V AC
Resistance, Capacitance, Frequency, Diode Test
Temperature
3
EN
Maximum Input
2000A DC/AC
1000V DC/AC
600V DC/AC
600V DC/ AC
EN
2. Description

Meter Description

1. NCV Test
2. Current clamp
3. Non-contact AC voltage indicator light
4. Clamp trigger
5. Rotary Function switch
6. HZ/% REL and Flashlight button
7. HOLD and Backlight button
8. MAX/MIN button
9. PEAK and INRUSH button
10. MODE select and Bluetooth button
11. LCD display
12. V Ω Diode Continuity CAP TEMP Hz% jack
13. COM input jack
14. Battery Cover

3. Display icons Description

Hold
Data Hold
Negative reading display
0 to 5999
Measurement display digits
REL/DCA Zero
Pmax/Pmin
PEAK Value (Voltage)
INRUSH
Inrush Current
MAX/MIN
Maximum/Minimum
Auto Power Off
AUTO
Auto Range mode
Direct / Alternating (Voltage and Current)
Low battery
mV or V
Milli-volts or Volts (Voltage)
Ohms
(Resistance)
A
Amperes (Current)
F
Farad (Capacitance)
Hz/%
Hertz (Frequency)/Percent(duty ratio)
o
o
F and
C
Fahrenheit and Celsius units (Temperature)
n, m, μ, M, k Unit of measure prefixes: nano, milli, micro, mega, and kilo
KPA-1000
•)))
Continuity test
Diode test
Analog Bargraph
Bluetooth4.0
4

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

0767488

Tabla de contenido