Installation
8) Insert pivot rod (V9) through spring
clip (V12) and clevis strap (V13).
Secure with spring clip (V12).
Adjust linkage if necessary.
V13
V9
Maintenance
1) Turn off water supply. Loosen and
remove the handle set screw (C)
and handle (B).
B
2

Troubleshooting Chart

Problem
Finish is spotting.
Symmons Industries, Inc.
Copyright © 2016 Symmons Industries, Inc.
9) Connect hoses (T) to spout and
valve body water connections
(K and P).
V12
T
2) Remove escutcheon (E) and nut (G).
C
Elements in water supply may cause
water staining on finish.
31 Brooks Drive
1
P
1
1
1
K
E
1
2
G
Cause
Braintree, MA 02184
Phone: (800) 796-6667
symmons.com
gethelp@symmons.com
10) Using a wrench, attach supply
lines to IPS inlet connections (Q)
and shut off valves. DO NOT
overtighten.
2
Q
1
4
3
11) Turn on water supplies. Remove
aerator (F) and flush lines free of
debris. Check for leaks.
3) Remove cartridge (H and/or I)
and inspect for debris. Replace
cartridge if necessary.
H
4) Install cartridge following steps
1 & 2 in reverse.
Solution
Clean finished trim area with a soft
cloth using mild soap and water or a
non-abrasive cleaner and then quickly
rinse with water.
Fax: (800) 961-9621
ZV-3206 REV 0
050216
1
I

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Slw-6712-1.5

Tabla de contenido