Troubleshooting Chart - Symmons Identity SLS-6710-1.5 Manual De Operaciones Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation
7) Attach supply lines (M) to shut-off
valves and hand tighten. Using a
wrench, finish with one-half turn.
DO NOT overtighten.
M
1
1
Maintenance
1) Turn off water supply. Remove plug
button (B). Loosen and remove the
handle set screw (C), handle (A),
collar (D) and nut (E).
3
A
B
D
4
E

Troubleshooting Chart

Problem
Finish is spotting.
Symmons Industries, Inc.
Copyright © 2016 Symmons Industries, Inc.
8) Remove flow restrictor (J) and flush
supply lines free of debris. Check
for leaks.
2
2) Remove cartridge (H) and inspect
for debris. Replace cartridge if
necessary.
C
5
Elements in water supply may cause
water staining on finish.
31 Brooks Drive
Braintree, MA 02184
symmons.com
J
H
Cause
Phone: (800) 796-6667
gethelp@symmons.com
9) Optional: Adjust limit stop washer
to limit handle turn to the hot
position if desirable.
2
1
Note: Counterclockwise to lower
temperature, clockwise to increase
temperature.
3) Install cartridge following steps
1 & 2 in reverse.
Solution
Clean finished trim area with a soft
cloth using mild soap and water or a
non-abrasive cleaner and then quickly
rinse with water.
Fax: (800) 961-9621
ZV-3204 REV 0
040416
3

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Identity sls-6712-1.5

Tabla de contenido