ONCE THE ELECTRIC CONNECTION HAS BEEN PERFORMED, THE AUTHORIZED
TECHNICIAN (ELECTRICIAN) MUST ISSUE A DECLARATION CERTIFYING THE
MEASUREMENT OF THE CONTINUITY OF THE EQUIPOTENTIAL PROTECTION
CIRCUIT.
THE APPLIANCE IS TO BE SUPPLIED THROUGH A RESIBASIC CURRENT DEVICE
(RCD) HAVING A RATED RESIBASIC OPERATING CURRENT NOT EXCEEDING 30 MA

TERMINAL BOX

The terminal box is placed externally on the back of the oven.
Single phase, one chamber
Single phase, two chambers and versions 9 single
phase
Three phase one chamber and two chambers
Three phase from versions 9 and up

EQUIPOTENTIAL

The equipment must be connected with an equi-potential system . the connection terminal is located near
the terminal box. The bonding wire must have a minimal section of 10 mm ².
13
L1
L2
L3
N
Oven type
Clamp N. 1
Clamp N. 2
Clamp N. 3
Clamp N. 5
Clamp N. 6
N. of cables
Section (mm²)
3
3
5
5
4
6
4
6