The compressor must be disposed in conformity with the methods
provided for by local regulations.
G
B
TABLE 1 – MAINTENANCE
FUNCTION
Cleaning of intake filter and/
or substitution of filtering
element
Change of oil*
Tightening of head tension
rods
Draining tank condensate
* For lubricated models only
4
POSSIBLE FAULTS AND RELATED PERMITTED REMEDIES
FAULT
Leakage of air from the valve of the pressure
switch with the compressor off.
Reduction of performance. Frequent start-up.
Low pressure values.
The compressor stops and restarts
automatically after a few minutes.
In the V, 3 HP versions, it is does not start.
After a few attempts to restart, the compressor.
The compressor does not stop and the safety
valve is tripped.
AFTER THE
EVERY 100
EVERY 300
FIRST 100
HOURS
HOURS
HOURS
●
●
At start-up and after the first hour of work
Periodically and at the end of work
Check valve that, due to wear or dirt on the seal,
does not perform its function correctly.
Excessive performance request, check for any
leaks from the couplings and/or pipes. Intake
filter may be clogged.
Tripping of the thermal cutout due to
overheating of the motor.
Tripping of the thermal cutout due to
overheating of the motor (removal of the
plug with the compressor running, low power
voltage).
Irregular functioning of the compressor or
breakage of the pressure switch.
●
CAUSE
12
REMEDY
Unscrew the hexagonal head of the check
valve, clean the valve seat and the special
rubber disk (replace if worn). Reassemble and
tighten carefully (figures 14a-14b).
Replace the seals of the fitting, clean or replace
the filter.
Clean the air ducts in the conveyor. Ventilate
the work area. Reset the thermal cutout. On
lubricated and V type models, check oil level
and quality. On V models, have the voltage
checked.
Activate the on/off switch. Ventilate the work
area. Wait a few minutes. The compressor will
restart independently. On V, 3 HP models, reset
the thermal cutout. Remove any power cable
extensions.
Remove the plug and contact the Service
Center.