Use; Control Panel - PLYMOVENT MOBILEGOplus Manual De Instalación Y De Uso

Aspirador fijo para humos de soldadura con dos brazos fle
Ocultar thumbs Ver también para MOBILEGOplus:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

A (8x)
B (8x)
C
Fig. 4.1 Rotating flange
Fig. 4.2
• In case of a hose tube arm: put the hose tube over the
internal rods of the arm.
• Move the hose clamp (C) and the arm swivel ring (incl.
rubber collar) (D) over the hinge rod (B).
• Put the washer M20 (E) on the rotating flange (F).
• Put the hinge rod (B) in the rotating flange (F).
• Put the hose (A) over the arm swivel ring (D).
• Use the rubber collar to make the connection airtight.
• Attach the hose (A) to the swivel ring (D) with the hose
clamp (C).
aTTENTioN!
Make sure to install the washer M20 (E) between
the rotating flange and the swivel ring to avoid
damage.
Fig. 4.2 Arm on mobile unit
4.4
Mounting of the hood
To install the extraction hood, do the following.
Fig. 4.3
• Loosen the mounting material that is attached to the hood
hinge.
• Install the extraction hood (G) with the bolt (F), 2 washers
(E), 2 spring washers (D) and a locknut (C).
• Install the hood collar (H) to the hood (G). Fasten it with
the clip.
• Install the hose tube (A) to the hood.
• Fasten the hose tube with a hose clamp (B).
0000115336/010518/0 MobileGo
A
B
C
D
E
F
60Hz
plus
A
B
C
D
E
F
D (2x)
Fig. 4.3 Hood mounting
5

uSE

WaRNiNg!
Fire hazard! Do not use the product for polishing
applications in combination with grinding, welding or
any other application that generate sparks.
Refer to chapter 3 / Safety instructions / Use.
5.1

control panel

The unit contains the following controls and indicators:
Fig. 5.1
A
Tumbler switch 0-1
B
Service indicator (red LED)
Fig. 5.1 Controls and indicators
5.2
use
Since it concerns a mobile unit, you can use it at any desirable
place. For optimal results you must place the unit as close as
possible to the source of pollution.
• Position the hood of the connected extraction arm at
400-800 mm (16-32 in.) from the source of pollution. Refer
to Fig. III on page 24 for the correct position.
• Make sure that the shut-off damper (ref. Fig. 2.1A) is open.
• Put the unit on (ref. Fig. 5.1A).
• Start welding.
• When the welding position changes, move the hood to the
correct position in relation to the weld.
A
B
C
A
A
B
C
D
F
E
E (2x)
F
G
H
B
EN - 6

Publicidad

Tabla de contenido
loading