Altrad Belle BHB BREAKERS Manual Del Operador página 42

Tabla de contenido

Publicidad

machine by depressing the start and stop device Then disconnect the hydraulic hose from the machine.
Use only authorized parts. Any damage or malfunction caused by unauthorized parts will not be covered by Warranty or Product
Liability.
Change damaged parts immediately.
Replace worn components in good time.
Always clean the hose couplings before mounting or dismounting.
Always plug hoses and nipples with clean and tight plugs when dismounting.
When cleaning mechanical parts with solvent, make sure to comply with occupational health and safety regulations, and make sure
that there is satisfactory ventilation.
For major service to the machine, contact the Altrad Belle or your nearest authorised dealer.
NOTE!
the machine is safe and correctly sited on the ground.
Routine Maintenance
Clean and inspect the machine.
Check Hoses and Fittings for cracks or leaks. Replace if necessary.
Inspect the 'Steel' for wear and damage. Do not use an worn or damaged 'Steel'.
Check for general damage to the machine.
be checked.
Check that the springs are not damaged.
Check the Chisel bushing in the nose for wear and damage.
Check moving parts, seals and bolts for wear and cracks. Replace if necessary.
Check the function of the machine.
Too big a clearance between the working tool's shank and the chisel bushing will generate increased vibrations. To avoid exposure
to excessive vibrations, check the chisel bushing for wear every day. Use the gauge that corresponds to the working tool's shank
also "Checking for wear" section for checking the working tool's shank.
Service and Maintenance
A
B
42
Every Week
Every 3
Months
Every 600
Hrs / Yearly

Publicidad

Tabla de contenido
loading

Tabla de contenido