Selection Of Installation Place - EQUATION EQ3-9K Manual De Instalación

Ocultar thumbs Ver también para EQ3-9K:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 15
Installation Procedure - Indoor unit

Selection of Installation Place

• Place, robust not causing vibration, where the body can be supported sufficiently.
FR
• Place, not affected by heat or steam generated in the vicinity, where inlet and outlet of the unit are not disturbed.
• Place, possible to drain easily, where piping can be connected with the outdoor unit.
• Place, where cold air can be spread in a room entirely.
ES
• Place, nearby a power receptacle, with enough space around.
• Place where the distance of more than lm from televisions, radios, wireless apparatuses and fluorescent lamps can be left.
• In the case of fixing the remote controller on a wall, place where the indoor unit can receive signals when the fluorescent lamps in the
PT
room are lightened.
Drawing for the installation of indoor units
IT
more than 15 cm
EL
more than 10 cm
PL
RU
KZ
UA
Moving the drain hose
RO
The drain pipe can be placed to the right
or left:
1 - Unplug the hose
EN
2 - Remove the cap on the opposite side
3 - Plug the pipe on the opposite side
4 - Place the cap at the old pipe location
Fitting of the Mounting Plate and Positioning of the
wall Hole
1 - Carry out, based on the neighboring pillars or lintels,
a proper leveling for the plate to be fixed against the
wall, then temporarily fasten the plate with one steel
nail.
2 - Make sure once more the proper level of the plate, by
hanging a thread with a weight from the central top
of the plate, then fasten securely the plate with the
attachment steel nail.
3 - Find the wall hole location A/C using a measuring
tape
128
The distance between the indoor unit and the floor should be more than 2m.
Please be subject to the actual product purchased,the above picture is just for your reference.
Attention must be paid to
the rising up of drain hose
more than 10 cm
A=120mm
B=
60mm
Ø
A=150mm
B=
Ø
60mm
A=70mm
Arrangement of piping
directions
Rear left
Left
Rear right
Right
Below
C=80mm
C=120mm
B=
Ø
60mm
C=113mm

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido