Multimetrix DM 92 Manual De Instrucciones página 16

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

English
Functional Description
Taking measurement
in dual unit mode
Process
Helpful measuring
hints for dual unit
mode
16
Select dual unit mode by sliding the switch on the side of the receiver
to the corresponding position (▪▪).
Select ON on the side of the target. Light on front of the target will
blink slowly indicating target is on.
Place the target at one of the end of the distance to be measured (the
measurement will be taken from the back of the target).
Walk with the receiver to the other end of the distance to be measured
and aim the receiver directly at the face of the target. (aiming at an
angle to the face of the target will decrease the maximum distance the
DM 92 can measure).
Make certain you have a clear path to the target.
Press the measurement key until a consistent measurement appears
(about 5 seconds) the unit will display rapid measurement as long as
the key is held. Release the key to freeze the measurement.
1. Make certain there is a clear line of sight between the receiver and the
target
2. Use validate mode when targeting measurements near traffic,
construction or other noise sources
3. The target is not affected by noise. If there are loud noise such
sources such as machinery, traffic, etc. , arrange the measurement so
the receiver is furthest from the noise source
4. Use the dual unit mode operation even for short measurements if there
are obstacles in the path of the measurement
5. If the wind is gusting, make certain you use validate mode for
measurements (see the section on environmental conditions)
6. When measuring distances beyond the maximum range break the
measurement into 2 or more measurements and use the "add" function
to sum them.