WARNING:
YOURSAFETYISIMPORTANTTOYOUANDTOOTHERS,
SOPLEASEREADTHESEINSTRUCTIONSBEFOREYOU
OPERATETHISHEATER.
GENERAL HAZARD WARNING:
FAILURETOCOMPLYWITHTHEPRECAUTIONSAND
INSTRUCTIONSPROVIDEDWITHTHISHEATER,CAN
RESULTINDEATH,SERIOUSBODILYINJURYAND
PROPERTYLOSSORDAMAGEFROMHAZARDSOF
FIRE,EXPLOSION,BURN,ASPHYXIATION,CARBON
MONOXIDEPOISONING,AND/ORELECTRICALSHOCK.
ONLYPERSONSWHOCANUNDERSTANDANDFOLLOW
THEINSTRUCTIONSSHOULDUSEORSERVICETHIS
HEATER.
IFYOUNEEDASSISTANCEORHEATERINFORMATION
SUCHASANINSTRUCTIONSMANUAL,LABELS,ETC.
CONTACTTHEMANUFACTURER.
WARNING:
CARBON MONOXIDE CAN KILL
USINGAPORTABLEHEATERINANENCLOSEDAREA
CANPRODUCEDEADLYCARBONMONOXIDE.NOTFOR
HOMEORRECREATIONALVEHICLEUSE
CONTENTS
Specifications . ................................................................... 2
SafetyPrecations . .............................................................. 3
Storage&Service............................................................. 5
WiringDiagram................................................................ 6
PartsList . .......................................................................... 7
ExplodedViewDrawing.................................................... 7
Force-Air Propane Construction Heater
WARNING:
FIRE,BURN,INHALATION,ANDEXPLOSIONHAZARD.
KEEPSOLIDCOMBUSTIBLES,SUCHASBUILDING
MATERIALS,PAPERORCARDBOARD,ASAFEDISTANCE
AWAYFROMTHEHEATERASRECOMMENDEDBYTHE
INSTRUCTIONSNEVERUSETHEHEATERINSPACES
WHICHDOORMAYCONTAINVOLATILEORAIRBORNE
COMBUSTIBLES,ORPRODUCTSSUCHASGASOLINE,
SOLVENTS,PAINTTHINNER,DUSTPARTICLESOR
UNKNOWNCHEMICALS.
THE STATE OF CALIFORNIA REQUIRES THE
FOLLOWING WARNING:
WARNING:
COMBUSTIONBY-PRODUCTSPRODUCEDWHENUS-
INGTHISPRODUCTCONTAINCARBONMONOXIDE,
ACHEMICALKNOWNTOTHESTATEOFCALIFORNIA
TOCAUSECANCERANDBIRTHDEFECTS(OROTHER
REPRODUCTIVEHARM).
THISPRODUCTCONTAINSCHEMICALSKNOWNTO
THESTATEOFCALIFORNIATOCAUSECANCERAND
BIRTHDEFECTSOROTHERREPRODUCTIVEHARM.
SPECIFICATIONS
MODELNO........................................................400FAVT
GASTYPE . .......................................................... Propane
BTURATING.............................. 210,000-400,000BTU/hr
GASSUPPLYPRESSURETOREGULATOR
Maximum: Bottle Pressure, Minimum: 20 psig (0.14 MPa)
REGULATOROUT................................ 20psig(0.14MPa)
ELECTRICALINPUT.........................1 15V,60Hz,1Ø,5.5a
IGNITION........................... DirectSpark,interruptedtype
PRIMARYFLAMECONTROL . . SolidState,10-15sec.timing
HIGHTEMPERATURECONTROL................... 240°F(1 16°C)
MinimumAmbientTempRating:0°F(-17.8°C)
FUELCONSUMPTION.............................9.3-18.5lbs/hr
FUELORIFICEPORTNO.:
FUELORIFICEPORTSIZE: . ..................................2.35MM
HEATEDAIROUTPUT: . ............ 1400CFM(39.6CU-M/M)