Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

ATTENTION: Before starting up, please read carefully the following
paragraphs which describe the programming and main settings of
the automation. While programming, follow strictly the order and
the indicated instructions. Do not enter in the action range of the
automatism while it's in movement or while programming. Before
carrying out any modifies please wait that there is a completely
standstill of the automatism. Do not allowed external and or not
qualified personal to carry out any operations and/or presences in
the action range of the system.
P
OWER SUPPLY
When the control panel is powered will hear 2 buzzer sounds.
SIMULTANEOUSLY COME ON THE "POWER" GREEN LED TO
INDICATE THE POWER PRESENCE.
S
ELECTABLE FUNCTIONS THROUGH THE DIP SWITCH
DIP1:
- If positioned on OFF: the active function in the
OPENING BUTTON is the one called "DEAD MAN
OPERATION". The opening of the automation
continues until the button itself is pressed. When
the button is released the automation stops.
- If positioned on ON: A momentarily pressing of
the OPENING BUTTON determines the complete
opening of the automation. The opening can be
stopped with the stop button or by a close operation
in any moment.
DIP2:
- If positioned on OFF: The active function in the CLOSING BUTTON
is the one called "DEAD MAN OPERATION". The closing of the
automation goes on until the button itself is pressed. When the button
is released the automation stops.
- If positioned on ON: A momentarily pressing of the CLOSING BUTTON
determines the complete closing of the automation. The closing can be
stopped with the stop button or by an open operation in any moment.
DIP3: WORKING TIME
- If positioned on OFF: the automation has a maximum working time
of 3 minutes.
- If positioned on ON: the automation has an infinitive working time.
DIP4: INPUT WORKING (as you can see in the scheme on the previous
page).
- If positioned on OFF: you have the possibility to connect three buttons
4
5 6 7
"STOP, OPEN, CLOSE" on the control board. In this case the DIP 1 and
the DIP2, as mentioned above, will determine the working modality of
the inputs.
- If positioned on ON: you have the possibility to connect the operations
of two buttons "STOP, STEP by STEP" on the control board. In this
case the working will be determined by the sequence OPEN-STOP-
CLOSE....
The DIP1 and DIP2 needs to be set on ON for enabling this function.
C
OURTESY LAMP
You can connect a courtesy light 230Vac 40W max. to the 6 and 7
terminals. The lamp lights up with a OPEN or CLOSE button command
and stays on for 3 minutes.
8 9 1
0
11
11
A
DDITIONAL POWER SUPPLY
Through E and F terminals, you can use a voltage 24Vdc (200 mA) for
accessories.
P
HOTOCELLS CONNECTION
F
The contact connection of the photocells must be executed in series to
E
the STOP button input (terminal A).
D
T
ECHNICAL DATA
C
Power supply voltage
B
Frequency
Max. single motor power
Max. card power absorption
A
Protection degree
Fuse
Dimensions
Weight of the equipment
1 1 1
1 2 3
230V~ ±10%
50/60Hz
500W
20 mA
IP55
6.3A ritardato
250x196x100 mm
1,2 kg
1
4 5 6
1
1
G
B
1

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Abj0004

Tabla de contenido