to the D+TEST and D- outputs (DIP13 ON). Automatically, every time
the gate completes a full opening, just before closing, the control board
switches OFF the D+TEST and D- power supply output for a very short
time. While the safety strip power supply is switched OFF, if everything
is working fine the safety strip contact (EDGE - COM) must open. In
case the test fails, no other gate manoeuvre will be allowed.
NOT ALL THE
SAFETY STRIPS CAN
SWITCH DIP13 MUST BE LEFT OPEN.
BLINKER
Connect the flashing light to the blinker output, use flashing lights
ACG7059 and bulbs of 40W maximum.
PRE-FLASHING function
The DIP 5 in the ON position enables the pre-flashing, the BLINKER
starts flashing 3 seconds before every movement of the gate.
The DIP 5 in the OFF position disables any pre-flashing, the BLINKER
starts flashing and the motors will start at the same time.
BUZZER
The current supplied to the Buzzer will be 200 mA at 12Vdc.
During the normal operation of the gate, opening and closing, the
buzzer will buzz intermittently. Only during the alarm situations (safety
strip) the buzzing will almost be constant.
GATE OPEN INDICATOR (SIGNAL - COM)
Should you need to have an indication about the leaf position, the
output SIGNAL - COM can be connected to a 12Vdc bulb of 3W
maximum. It is turned ON when the gate is open or partially open, it is
turned OFF only when the gate is completely closed.
WE RECOMMEND NOT TO OVERLOAD THE INDICATOR OUTPUT
(SIGNAL - COM) OTHERWISE THE GATE FUNCTIONING COULD BE
COMPROMISED OR THE CONTROL BOARD COULD BE DAMAGED
RESTORATION OF OPERATIONS AFTER A BLACKOUT
If DIP 11 is turned OFF the blackout function is DISABLED.
If DIP 11 is turned ON the blackout function is ENABLED.
In case of a blackout occurs and the blackout function is enabled
(DIP11 ON), when the main power returns, automatically the operator
will function according to the chart 2.
During blackout
If the gate is totally closed
If the gate is at the opening stage
If the gate is totally open (with dip 3 OFF)
If the gate is totally open (with dip 3 ON)
If the gate is in the closure stage
If the gate is in the safety edge alarm
BE TESTED, THUS THE
TABLE 2
At the return of the network
power supply.
It will remain closed
It will continue opening
It remains open. Consequently
closing operations of the gate
can be controlled.
It remains open, but at the
expirery of the automatic
closure time closure operation
starts off.
It continues closing.
The safety edge alarm starts
off again.
T
ECHNICAL SPECIFICATIONS
- Temperature range
- Humidity
- Power supply voltage
- Frequency
- Maximum absorption
- Interruptions in electricity supply
- Maximum power of gate open indicator 12Vdc 3W (equivalent to 1
- Maximum load of blinker output
- Current available for photocells and accessories 500mA 12Vdc
- Current available on radio connector
TECHNICAL RADIO SPECIFICATIONS (Only CRX models)
- Reception frequency
433,92MHz
- Impedance
52
- Sensitivity
>2.24 V
- Excitation time
300ms
- De-excitation time
300ms
- Codes in store
N° 60
- All the inputs must be used as clean contacts because the power
supply is generated internally (safe voltage) in the card and it is
set in a way to guarantee the use of the double insulation and
reinforced in relation to parts with hazardous voltage.
- Any external circuits connected to the outputs of the control
board, must be carried out to make sure the double or reinforced
insulation is used in relation to parts with hazardous voltage.
- All the inputs are run by a programmed integrated circuit which
carries out a self-check at the beginning of each operation.
-10 ÷ + 55°C
< 95% without condensation
230 o 120V~ ±10%
50/60 Hz
32 mA
100ms
bulb of 3W or 5 LED with
serial resistance of 2,2 k )
40W with resistive charge
200mA 12Vdc