Measuring range
50 nF
500 nF
5 µF
50 µF
100 µF
The measuring duration depends on the capacitor size and might take up to 20 seconds.
* The measuring accuracy is specified for measured values from 10 nF and for previ-
ous null balance by means of the „RANGE/ REL Δ (
7.6 Frequency ranges
Overload protection for frequency measurements: 600 V
7.6.1
Frequency ranges for square wave signals (Switch setting: Hz, %)
Measuring
Resolution
range
5 Hz
50 Hz
500 Hz
5 kHz
50 kHz
500 kHz
5 MHz
7.6.2
Frequency indication for sinusoidal signals (Switch setting: V
actuation of the „SELECT" key:
Measuring accuracy: ± (0.3 % + 5 digits) applies to sinusoidal voltages of up
to 600 V
(V
) higher than 50 % of the final measuring range value
AC
7.7 Pulse duty ratio for square wave signals (Switch setting: Hz, %)
Overload protection in the case of pulse ratio measurement: 600 V
Meas. range
0.1 % - 99.9 %
8.

Measuring with the BENNING MM P3

8.1 Preparing the measurement

Operate and store the BENNING MM P3 at the specified storage and operating tem-
peratures only! Do not permanently expose the device to sunlight.
-
The connected black and red safety measuring leads comply with the valid provi-
02/ 2018
Resolution
10 pF
100 pF
1 nF
10 nF
100 nF
Measuring accuracy for 5 V
0.001 Hz
± (0.3 % of the measured value + 5 digits)
0.01 Hz
± (0.3 % of the measured value + 5 digits)
0.1 Hz
± (0.3 % of the measured value + 5 digits)
1 Hz
± (0.3 % of the measured value + 5 digits)
10 Hz
± (0.3 % of the measured value + 5 digits)
100 Hz
± (0.3 % of the measured value + 5 digits)
1 kHz
± (0.3 % of the measured value + 5 digits)
(10 Hz - 500 Hz) and displayed values in the AC voltage range
eff
Resolution
0.1 %
± (0.5 % of the measured value + 3 digits) > 1.0 V
BENNING MM P3
Measuring accuracy
± (5.0 % of the measured value + 0.2 nF)*
± (2.9 % of the measured value + 5 digits)
± (2.9 % of the measured value + 5 digits)
± (2.9 % of the measured value + 5 digits)
± (2.9 % of the measured value + 5 digits)
(square wave signal)
Measuring accuracy up to 5 V
(square wave signal, 5 Hz - 5 kHz)
)" key 6
eff
max.
Sensitivity
SS
> 1.0 V
> 1.0 V
> 1.0 V
> 1.0 V
> 1.0 V
> 1.0 V
> 1.0 V
, Hz, %) and
AC
eff
Sensitivity
SS
(30 % ≤ % ≤ 70 %)
(rectangle)
ss
(rectangle)
ss
(rectangle)
ss
(rectangle)
ss
(rectangle)
ss
(rectangle)
ss
(rectangle)
ss
(rectangle)
ss
19