Mains Power Supply - GYS POWERDUCTION 10R Manual De Instrucciones

Ocultar thumbs Ver también para POWERDUCTION 10R:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 20
Translation of the original instructions
Fig.1
1
The elements contained in this carry case are fragile. They're to be handled with care.

MAINS POWER SUPPLY

This equipment is supplied with a 16 A CEE7/7 type plug and should only be used on an electrical installation
single-phase 230 V (50 - 60 Hz) three-wire with a neutral connected to earth.
STARTING
Assembly
Choose the required tool (one of the 3 coiled wires, the braided wire or the straight wire) and fit it on the inductor. To
do so, insert the two rods of the selected tool and insert them into the holes intended for this purpose, then screw the
tightening wheels (fig.2). To unscrew a tightening wheel, it is possible to use a spanner/wrench size 12. Warning :
never use a spanner/wrench to screw the tightening wheel as it may get damaged.
Heating activation
Start the product by pressing the ON/OFF button.
Press the inductor button to activate the heating. Keep
pressing the button to keep the heating active.
Protections
The product is equipped with protections :
Thermal protection
Overcurrent protection
Trigger defect
RECOMMENDATIONS
The coiled inductor is designed for unjamming. it heats metal pieces or parts via induction to unblock and remove them
easily. Circle the piece using the appropriate accessory (coiled, braided, straight), then heat the inductor, that will be
used to heat the metal piece. Once the piece starts to be coloured in red, stop the heating and remove it using the right
tool (clamp, spatter/wrench...) then remove it.
POWERDUCTION 10R
The orange LED is lit when the product is in thermal protection. The product trigger
is inactive during this time. Wait for the orange LED to go out before restarting the
heating process.
In case of overcurrent, the orange LED flashes. The product trigger becomes inactive.
Restart the product to clear the fault and restart heating.
On power-up, if the Powerduction detects a fault on the trigger, the orange LED lights
up. Disconnect the faulty trigger and replace it. Then restart the heater.
2
3
4
The green LED lights up.
The green LED flashes green as long as the heating is
active.
EN
Coiled wired Ø18 mm
054806
Coiled wired Ø24 mm
054790
Coiled wired Ø30 mm
055469
Flexible braided wire
054813
Straight rigid wire
054868
11

Publicidad

Tabla de contenido
loading

Tabla de contenido