CV
Explanation
66
PoM
Forward trim
67
PoM
Speed table speed level 1 (Vmin) to
-
94
PoM
speed table speed level 28 (Vmax)
95
PoM
Reverse trim
PoM
145
Switching range
Storing different states:
Bit 0: Storing function states
173
PoM
Bit 1: Storing speed
Bit 2: After a reset starting up with/without ABV
Bit 3 - 7: always 0
Storing different states:
174
PoM
Bit 0: Storing direction of travel
Bit 1 - 7: always 0
176
PoM
Vmin Analog DC
177
PoM
Vmax Analog DC
178
PoM
Vmin Analog AC
179
PoM
Vmax Analog AC
PoM must be supported by the locomotive controller / central controller.
CV Table for DCC
Values
Default
0 - 255
128
0 - 255
0 - 255
128
128
0 - 128
0 / 1
0 / 2
0 / 4
0 / 1
0 - 255
50
0 - 255
170
0 - 255
60
0 - 255
190
Notes
The CV value divided by 128 gives the fac-
tor with the speed level is multiplied when
the locomotive is running forward.
The CV value divided by 128 gives the fac-
tor with the speed level is multiplied when
the locomotive is running in reverse.
128 = 50% of speed level, 64 = 25% of
speed level
0 = do not store, value = store
7
Individual values must be added.
0 = do not store
1
1 = store
Must be smaller than CV 177
Must be larger than CV 176
Must be smaller than CV 179
Must be larger than CV 178
37