The motor can be wired in parallel. In this case, take into
account the maximum load of the switch or controller used.
The phases and neutrals of each motor must be
interconnected respectively.
Do not use multi-pole cables to control several motors.
Each motor must be connected to its own power cable.
2. 3. SET UP
Use universal adjusting cable 9015971 (follow the instructions in the corresponding manual for
connection), or use a non-locking double push-button switch to adjust settings.
Follow the following steps for set-up:
Checking the rotation direction (§2. 3. 1)
1)
Setting the end limits (§2. 3. 2)
2)
Setting advanced functions (§2. 3. 3)
3)
2. 3. 1. Checking the rotation direction
Switch the mains power supply back on.
1)
Press the "Up" button at the control point:
If the driven product raises, the wiring is correct, go to end
•
limits setting step (§2.3.2).
If the driven product is lowered, go to the next step.
•
Switch off the power.
2)
Reverse the brown wire and the black wire connected
-
to the control point.
Switch the power back on.
3)
Press the "Up" button to check the direction of rotation.
-
2. 3. 2. Setting the end limits
The procedure used to set the end limits depends on the equipment of the driven product (see table
below).
Pressing and holding the "Up" or "Down" buttons causes the driven product to raise or lower
continuously.
Pressing the "Up" or "Down" buttons briefly causes the driven product to raise or lower briefly.
Available devices
Top stop
k
-
* This step is especially suitable for "ZIP screens" or for any other specific driven product with a heavy
load bar and a top stop.
Use universal adjusting cable 9015971 (follow the instructions in the corresponding manual for
connection), or use a non-locking double push-button switch to adjust settings.
Copyright © 2016 Somfy SAS. All rights reserved.
Heavy load bar
l
-
-
L2
1)
2)
3)
Steps to
performed
See E1
k
See E2
See E3*
Images not contractually binding
L1
N
M
M
ON
OFF
ON
EN
M
OK
2
OK
l
45