3.2.3 Hexadecimal Programming
Some sections require the entry of hexadecimal values A to F. Press the [#]
key to scroll through these values. If the value is left unchanged for two
seconds, Grafica will automatically select it and move forward to the next digit.
4.0 System Options
The following sections detail Grafica's programing options.
4.1 Partition Assignment
S
[001]: O
ECTION
Each keypad in the system can be assigned to one or more partitions. In
section [001], options [1] to [8] represent partitions 1 through 8 respectively.
To assign the keypad to a partition, enable the option that corresponds to the
desired partition. By default, partitions 1 to 8 are enabled.
Options [5] to [8] are available with DigiplexNE (DGP-NE96) systems
only.
4.2 Display Code Entry
S
[002]: O
ECTION
This option determines whether the user's code # (PIN) is displayed on the
LCD screen when entering the PIN.
Option [1] OFF = Digits are replaced by asterisks (*) (default)
Option [1] ON = Code # (PIN) digits will be displayed
4.3 Display Exit Delay
S
[002]: O
ECTION
Based on the user's needs, an Exit Delay Timer can be programmed to
provide the user time to exit the partition before the system is armed. If this
option is enabled, the Exit Delay Timer's countdown will appear on the LCD
screen next to the hourglass icon.
Option [2] OFF = Exit delay time will not appear
Option [2] ON = Exit delay time will appear (default)
4.4 Display Entry Delay
S
[002]: O
ECTION
Based on the user's needs, an Entry Delay Timer can be programmed to
provide the user time to enter their code # (PIN) before the alarm is
triggered. If this option is enabled, the Entry Delay Timer's countdown will
appear on the graphic LCD screen next to the hourglass icon.
6 Reference & Installation Manual
[1]
[8]
PTIONS
TO
[1]
PTION
[2]
PTION
[3]
PTION