TROUBLE
1. Fan will not start (Warning:
THE ceiling must be switched
OFF, and the assistance of a
licensed
electrician
required.)
2. Fan Wobbles
(Refer to Wobble section of the
manual for further information.)
3. Fan sound noisy
4. Mechanical Noise
5. Light will not turn ON
(Optional light kit ONLY)
WARNING: THE CEILING FAN MUST BE SWITCHED OFF, BEFORE ANY TROUBLESHOOTING IS
PERFORMED.
FAN Models
Artemis F803
TROUBLE-SHOOTING CHECKLIST
PROBABLE CAUSES
A. Fuse or circuit breaker blown.
B. Loose power line connections to
the fan.
maybe
C. Speed controller not in correct
position.
A. Fan blades are not horizontal to
ceiling.
B. Blade screws are loose.
C. Blade/s are out of shape
A. Top canopy touching ceiling.
B. Loose fan blade screws.
C. Ceiling fan not secured against
ceiling.
D. Incorrect speed controller.
E. Audible buzzing noise. Cause by
Ripple Control signals. Please refer to
the Ripple Control section of this
manual.
A. Allow at least for 8 hours settling-in
period.
The globe/lamp has failed.
SPECIFICATION
Rated Voltage
220 - 240 VAC
Check main and branch circuit fuses or
circuit breakers.
Check line wire connections to fan
Check speed controller's position.
Refer to "wobbling fixing" section of
manual.
Make sure all
fastened.
Remove blade and lay on a flat surface to
check if blades are out-of-shape. Contact
agent or manufacturer for replacement
blades.
Lower Canopy from ceiling to ensure
minimum 3 mm clearance.
Re-tighten all screws on fan blades but
never over-tighten.
Re-tighten all screws in the hanging
bracket or plate.
Change the controller to the one supplied.
Install a Ripple Control filter. (Refer to the
Ripple control information in this manual.)
Replace globe/lamp
Rated power
Rated power lamp (for
(motor)
models with light only)
70W
15
SUGGESTED REMEDY
-
The blade may require adjustment
at the blade mounting screws;
-
The blade is out of shape, thus
causing wobbling. New blades set
will require to be replaced. Contact
your local Beacon Lighting store.
screws are securely
MAX 80W
Lamp type
R7S