5. INSTALL THE HOOD
5.1 Run power cable to installation location. Position the hood in its intended location. Using a pen, mark the position
of the screws (smaller part of the keyholes, see pictures below for the (5) keyholes locations). Remove the hood.
5.2 Install (4) #8 x ½'' screws, leaving a 1⁄8'' gap (do not install the #5 screw yet).
1
2
HD0115
5.3 Attach the wire clamp, insert the power cable in the hood and tighten the wire clamp to secure the cable. Place the
hood under the cabinet and slide it in position. Make sure the adapter/damper assembly enters the duct opening.
Tighten the (4) screws completely, then add the last screw (screw #5) in the center keyhole.Make sure the damper
flap opens freely.
6. CONNECT WIRING
Risk of electrical shock. Electrical wiring must be done by qualified personnel in accordance with
all applicable codes and standards. Before connecting wires, switch power off at service panel and
lock service disconnecting means to prevent power from being switched on accidentally.
Connect cable into wiring box using provided wire connectors.
Connect wires as follows: BLACK to BLACK, WHITE to WHITE and GREEN
or BARE wire under GREEN ground screw. DO NOT FORGET TO
CONNECT THE GROUND.
!
1
2
HD0122
WARNING
!
- 8 -
3
3
5
4
HD0123
GROUND
SCREW
HD0123
4