Technical data
Tool data
CP7755
Free speed (rpm) 7700
Max. torque (re-
1300
verse) (Nm)
Max. torque (re-
960
verse) (ft.lb)
Max. working
575
torque (Nm)
Max. working
425
torque forward
(ft.lb)
Min. working
80
torque (Nm)
Min. working
59
torque forward
(ft.lb)
Weight (kg)
1.85
Weight (lb)
4.0
Maximum working pressure
6.3 bar / 90 psig
Declarations
EU DECLARATION OF CONFORMITY
We, CHICAGO PNEUMATIC Tool Co. LLC, 1815 Club-
house Road, Rock Hill, SC 29730, declare under our sole re-
sponsibility that the product (with name, type and serial
number, see front page) is in conformity with the following
Directive(s):
2006/42/EC (17/05/2006)
Harmonized standards applied:
EN ISO 11148-6:2013
Authorities can request relevant technical information from:
Pascal Roussy, R&D Manager, Ets Georges Renault, 38 rue
Bobby Sands, BP10273 44818 Saint Herblain, France
Saint-Herblain,
Pascal ROUSSY
Signature of issuer
8
CP7755-
CP7755
2 Air
CP7755-
Air Flex
Flex
2
Mini
Mini
7700
7700
7700
1300
1300
1300
960
960
960
575
575
575
425
425
425
80
80
80
59
59
59
1.96
1.93
2.04
4.3
4.25
4.5
© Chicago Pneumatic - 8940175876
Noise and vibration
CP7755
Sound pres-
94
sure level
(dB(A))
Vibration (m/
8.5
s²)
Vibration un-
3.4
certainty
Uncertainty 3 dB(A), in accordance with EN ISO 15744. For
Sound power level, add 11 dB(A)
Vibration standard : ISO-28927-2
These declared values were obtained by laboratory type test-
ing in accordance with the stated standards and are suitable
for comparison with the declared values of other tools tested
in accordance with the same standards. These declared val-
ues are not adequate for use in risk assessments and values
measured in individual work places may be higher. The ac-
tual exposure values and risk of harm experienced by an indi-
vidual user are unique and depend upon the way the user
works, the workpiece and the workstation design, as well
upon the exposure time and the physical condition of the
user.
We, CHICAGO PNEUMATIC Tool Co. LLC, cannot be
held liable for the consequences of using the declared values,
instead of values reflecting the actual exposure, in an individ-
ual risk assessment in a work place situation over which we
have no control.
This tool may cause hand-arm vibration syndrome if its use
is not adequately managed. An EU guide to managing hand-
arm vibration can be found by accessing
www.pneurop.eu/index.php
lation'.
We recommend a programme of health surveillance to detect
early symptoms which may relate to noise or vibration expo-
sure, so that management procedures can be modified to help
prevent future impairment.
If this equipment is intended for fixtured applications:
The noise emission is given as a guide to the machine-
builder. Noise and vibration emission data for the com-
plete machine should be given in the instruction manual
for the machine.
Regional Requirements
WARNING
This product can expose you to chemicals including
lead, which is known to the State of California to cause
cancer and birth defects or other reproductive harm. For
more information go to
Impact Wrench
CP7755
CP7755-2
Air Flex
Air Flex
CP7755-2
Mini
Mini
94
94
94
7.9
8.5
12.9
1.8
3.4
1.8
http://
and selecting 'Tools' then 'Legis-
www.P65Warnings.ca.gov