Ac/Dc Voltage Measurements - Southwire 13050S Instrucciones De Operación

Multímetro de rango automático
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Operation
MODE BUTTON
The MODE button is used to select AC or DC voltage, Hz or % Duty Cycle, Ohms,
Diode Test, Continuity or Capacitance, and °F and °C.
MAX/MIN Button
1. Momentarily press the MAX/MIN button to activate the MAX/MIN mode. "MAX"
will appear on the LCD display and the meter will display and hold the highest
reading. The meter will update the reading when a higher "max" occurs.
2. Momentarily press the MAX/MIN button again to view the lowest reading.
"MIN" will appear on the LCD display and the meter will display and hold the
lowest reading. The meter will update the reading when a lower "min" occurs.
3. Press and hold the MAX/MIN button to end MAX/MIN and return to normal
operation.
NOTE: The meter does not Autorange when the MAX/MIN mode is active.
The display will read OL if the range is exceeded. MAX/MIN does not work on
Frequency, Duty Cycle, Diode Test, Continuity and Capacitance.
FLASHLIGHT Button
Press the
button to turn the flashlight on and off.
7
Operation cont.
HOLD/Backlight button
To freeze the reading on the display, momentarily press the HOLD
will appear on the LCD display while the reading is being held. Momentarily press
the HOLD
button again to return to normal operation.
The backlight illuminates the LCD display when the ambient light is too low to view
the displayed readings. To turn on, press the HOLD
on. To turn off, press the HOLD
button until the backlight turns off.

AC/DC Voltage Measurements

WARNING:
Observe all safety precautions
when working on live voltages.
1. Set the rotary function switch
to the
position.
2. Press the MODE button to select
AC or DC voltage. The AC "~" or
DC "
" symbol will appear on
the LCD display.
3. Insert the black test lead into
the COM input jack and the red
test lead into the V input jack.
4. Touch the test lead probes to the circuit under test.
If measuring DC voltage, touch the red test lead to the
positive side of the circuit and the black test lead to the
negative side of the circuit.
5. Read the voltage on the LCD display.
button. "HOLD"
button until the backlight turns
n m VA F M k
0
10
20
30
40
AUTO HOLD MAX MIN REL LOZ
n m VA F M k
MAX
MIN
0
10
20
30
AUTO HOLD MAX MIN REL LOZ
MAX
MIN
V
-
8
40
+

Publicidad

Tabla de contenido
loading

Tabla de contenido