Operation cont.

Temperature Measurements

WARNING:
Do not touch the temperature probe to live circuits.
1. Set the rotary function switch
to the °F °C position.
2. Press the MODE button to select
readings in °F or °C.
3. Connect the Temperature Probe to
the Banana Plug Adapter. Note the
– and + markings on the adapter.
Connect the adapter to the meter,
making sure the – side goes into
the COM input jack and the + side goes into the °F °C input jack.
4. Touch the tip of the Temperature Probe to the object being
measured. Keep the probe touching the object until the
reading stabilizes (about 30 sec).
5. Read the temperature on the LCD display.
n m VA F M k
0
10
20
30
40
AUTO HOLD MAX MIN REL LOZ
n m VA F M k
MAX
MIN
0
10
AUTO HOLD MAX MIN REL LOZ
MAX
MIN
13
Operation cont.

Battery Replacement

WARNINGS:
20
30
40
the meter before removing the battery/fuse cover.
1. Lift up the tilt stand.
2. Loosen the Phillips
screws on the battery/
fuse cover.
3. Remove the battery/fuse
cover.
4. Replace the batteries with
three AAA batteries.
5. Observe proper polarity
as shown inside battery
compartment.
6. Install the battery cover and
tighten the screws.
WARNING:
until the battery/fuse cover is securely fastened to the meter.
WARNING:
the battery compartment door firmly to maintain the waterproof and dust
proof integrity of the meter. Loose or overtightened screws, or an improperly
seated o-ring may compromise the meter's water and dust ingress protection.
To avoid electric shock, remove the test leads from
To avoid electric shock, do not operate the meter
When replacing the battery or fuses, be sure to secure
14