Operation cont.

Resistance Measurements

WARNING:
Never test resistance
on a live circuit.
1. Set the rotary function switch to the
2. Press the MODE button until the
" " symbol appears on the display.
3. Insert the black test lead into the
COM input jack and the red test
lead into the
input jack.
4. Touch the test lead probes to the
component under test. If the
component is installed in a circuit,
it is best to disconnect one side before testing
to eliminate interference from other devices.
5. Read the resistance on the LCD display.

Diode Test

WARNING:
Never test diodes
on a live circuit.
1. Set the rotary function switch to the
2. Press the MODE button until the
" " symbol appears on the display.
3. Insert the black test lead into the
COM input jack and the red test
lead into the
input jack.
4. Touch the test lead probes to the
diode under test.
5. Forward voltage will indicate 0.4 to
0.7 on the display. Reverse voltage
will indicate "OL". Shorted devices will indicate near 0
and an open device will indicate "OL" in both polarities.
n m VA F M k
n m VA F M k
0
10
0
10
20
30
40
AUTO HOLD MAX MIN REL LOZ
AUTO HOLD MAX MIN REL LOZ
MAX
MIN
position.
MAX
MIN
n m VA F M k
0
10
20
AUTO HOLD MAX MIN REL LOZ
MAX
MIN
position.
Red
Black
Black
Probe
Probe Probe
Forward test
Reverse test
11
Operation cont.

Continuity Measurements

WARNING:
on a live circuit.
20
30
40
1. Set the rotary function switch to the
2. Press the MODE button until the
" " symbol appears on the
display.
3. Insert the black test lead into the
COM input jack and the red test
lead into the
4. Touch the test lead probes to the
device or wire under test.
5. A beeper will sound if the resistance is approximately
50 or less and the resistance value will be shown
on the LCD display.
30
40

Capacitance Measurements

WARNING:
taking capacitance measurements.
1. Set the rotary function switch to
the
position.
2. Press the MODE button until the
"nF" symbol appears on the display.
3. Insert the black test lead into the
Red
COM input jack and the red test
Probe
lead into the
4. Touch the test lead probes to the
capacitor under test.
5. Read the capacitance value on
the LCD display. It may take up to a minute to get a
stable reading on large capacitors.
n m VA F M k
Never test continuity
0
10
20
30
AUTO HOLD MAX MIN REL LOZ
position.
MAX
MIN
input jack.
n m VA F M k
Safely discharge capacitors before
0
10
20
30
AUTO HOLD MAX MIN REL LOZ
MAX
MIN
input jack.
12
n m VA F M k
0
10
20
30
40
AUTO HOLD MAX MIN REL LOZ
40
MAX
MIN
n m VA F M k
0
10
20
30
40
40
AUTO HOLD MAX MIN REL LOZ
MAX
MIN