Checking precision
Caution!
The power tool may be adjusted
by authorised technicians only.
n Position the device at a distance of 10 m
parallel with a wall and switch on.
n Mark laser point "A" on wall.
n Rotate the device by 90° to the right and
mark laser point "B".
n Rotate the device by 180° and mark
laser point "C".
n Determine the horizontal difference
between points A, B and C.
– Maximum deviation: 4 mm
Note
If the deviation is greater than 4 mm,
have the device adjusted by authorised
technicians.
16

Maintenance and care

Cleaning
If the power tool is damp after use, wipe the
power tool and accessories with a dry, soft
cloth.
Do not use solvents or abrasive cleaning
agents to remove dirt. Use a clean cloth
moistened with water and a mild detergent.
Remove dust, etc. from the discharge
windows for the laser beams (1) with a soft
cloth.
Repairs
Repairs may be carried out by an authorised
customer service centre only.
Accessories
Spare-part/Accessory
Clamping column
Elevator tripod, medium-sized
(0.65–2.00 m)
Elevator tripod,
large (0.90–2.85 m)
ALP305
Order
no.
312.096
312.118
312.126

Publicidad