2. INSTALLATION
2.1 Safety instructions
The solar panels and cables should have Protection Class-II
Never connect the solar input of the inverter to a non-insulated
power supply and simultaneously to the grid.
If a non-insulated power supply is used to power the inverter for
configuration purposes, DO NOT connect the inverter to the grid:
this will cause serious damage to the inveter
When connected to a Victron MultiPlus or Quattro, please keep in mind that the Multi or
Quattro cannot charge batteries at a higher rate than its nameplate charge current.
A Multi 48/3000/35, for example can charge at max. 35A, which translates to a max. charge
power of 48 x 35 = 1680 W
Do not disconnect the DC-cables when the inverter is connected to the utility mains!
DC arcs will damage the connectors and could lead to serious burns and risk of fire.
Qualified personnel must install the inverter.
This inverter should be connected to a separate fuse in the breaker-box. No other household
devices should be connected to this.
Do not open the inverter!
High voltages inside the inverter are dangerous for life.
Even after the unit is disconnected from the grid and photovoltaic panels, high voltages may still
exist inside the PV-inverter.
Some parts and surfaces of the Inverter can become hot during operation. To reduce the risk of
injury, do not touch the heat sink at the back of the PV-Inverter or nearby surfaces while Inverter is
operating.
Do not install the inverter near explosive vapors or flammable items.
This unit is designed for outdoor usage
Do not expose the inverter to direct sunlight.
Direct sunlight increases the internal temperature which may reduce conversion efficiency.
Do not expose the inverter to rain.
Direct exposure to rain may, in course of time, increase humidity in the product, and ultimately result
in failure.
.
.
I P54).
(