Descargar Imprimir esta página

Facom 714P.200 Guía De Instrucciones página 5

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 14
Safety
Never perform any measurement on conductors of potential higher than 600V com-
pared to the ground.
- This ammeter clip is protected by double or enhanced isolation, requiring no
connection to the ground to ensure electric safety.
- This clip is for interior use only at an altitude < 2000m and in a Class 2 pollution environment
(according to EN 61010-2-032) – The ammeter clip is designed for taking measurements up to
600V for Class II measurement installations and up to 300V for Class III.
- Measurement Class II: includes measurements performed on circuits directly
connected to the low voltage installation - Measurement Class III:
includes measurements performed on building installation.
- The insulator provided on this ammeter clip delimits the protected section used
for handling the device. The ammeter clip must never be used when the
casing is broken, as the double isolation no longer ensures the
user's safety.
- This ammeter clip must remain connected to its associated multimeter when
taking any current measurement.
- Always disconnect the ammeter clip from any electric source before opening it.
Always comply with safety instructions to ensure safety of users at all times.
Symbols used on this ammeter clip:
Caution, Danger, Refer to the instructions.
Operation or removal authorized on conductors under hazardous voltage.
Apparatus fully protected by double or enhanced isolation.
Technical features
Ammeter clip
is an attachment of the multimeter
714P.200
Dimensions
Weight
Battery life
Measurement range
Operating temperature
Storage Temperature
Relative humidity in operation
Relative humidity of storage
IP Class
Maximum clamping diameter:
Supplied with a 2.0 m length cord with ending connector, instruction manual and warranty booklet.
protection casing
conductor clamping hole
and must be used with it.
714
: 134 X 62 X 34 mm
: 180g
: See features of controller
FACOM 714
:
(200A peak)
200A DC and 140A AC
:
-10° at + 65°C
:
-40° at + 80°C
:
<20 at 75% RH
:
(up to 40 ° C).
< 80% HR
:
IP50
(according to EN 60529)
: Ø 26mm cable
: Bar section: 25 X 5mm
2m L connected cord
jaw
Opening release
GB
5

Publicidad

loading

Este manual también es adecuado para:

727162