Alarm
Level
OFA First Alarm
(Time >70%)
OFA Second Alarm (Time = 100%)
Water flow (recirculation pump off)
System error
Calibration function
Factory parameters:
Language = FR (French)
Setpoint = Acid
Dosing method = Acid
OFA time (overload alarm) = OFF
Calibration = 7/4 (2 points
Flow input = ON
Code 0000137728 HPE
CAL
Enter
Esc
SET
OK
Screen
Level 7.2 pH
OFA alarm 7.2 pH
STOP OFA 7.2 pH
Flow 7.2 pH
Parameter error
Error 7 pH
Error 4 pH
OK
Relay
Relay closed
alarm
Relay open
alarm
Relay closed
alarm
Relay open
alarm
Relay open
alarm
Relay open
alarm
To restore the default parameters, proceed as follows:
Shut down the Basic system
Start up the Basic system by holding down the UP
and DOWN arrow keys.
The system will show
Press the UP arrow
Init.default Yes
Press Enter to restore the parameters.
rev.
5.0
F
M
I
Actions
- Press the Enter key to disable the
alarm remotely
- Restore the level of product in the
container
- Press the Enter key to disable the
alarm
- Press the Enter key to disable the
alarm
- Reactivate the water recirculation
pump.
- Press Enter to restore the default
parameters
- Damage to the system
- Replace the probe or the buffer
solution and repeat calibration
Init.default no
G
H
I
10