2
Horizontal and vertical levelling
The transport restraint must be released for horizontal
and vertical levelling. The LED (1) shows a permanent
!
green light. The laser lines flash as soon as the device
is outside the automatic levelling range of 3°. Position
the device such that it is within the levelling range.
The light of the laser linesis constant again.
3
Slope mode
Preparing the calibration check
It is possible for you to check the calibration of the laser.
To do this, position the device midway between 2 walls,
which must be at least 5 metres apart. Switch the device
on (LASER CROSS ON). The best calibration results are
achieved if the device is mounted on a tripod.
1. Mark point A1 on the wall.
2. Turn the device through 180° and mark point A2.
You now have a horizontal reference between points
A1 and A2.
1.
A1
2.
EasyCross-Laser Green
Release the transport restraint, push the slide
switch (3) to the left. The laser lines can be
switched individually with the selection button.
Do not release transport restraint, push slide
switch (3) to the right. Sloping planes can now
be measured. This mode cannot be used to
perform horizontal or vertical levelling as the
laser lines are no longer aligned automatically.
LED (1) and the laser lines flash green.