Mounting Instruction - RODCRAFT WP75P Manual Del Usuario

Prensa hidráulico
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 12
1. Technical Data (See figure 1.)
Dimension
Weight
Unit
[kg]
WP75P
498
WP100P
766
Dimension
F1
Unit
[mm]
WP75P
170
WP100P
114
Static coefficient test: 1.5 / Dynamic Coefficient test: 1.25 .
All values are current as of the date of this publication. For the latest information please visit www.rodcraft.com.
2. Machine type(s)
• The Units described here are operated manually and with Air-hydraulic support (optionnal), which apply pressure on parts for assembly or
disassembly purposes.
• For good use of the press never exceed the maximum capacity and never apply more pressure than necessary.
• No other use permitted. For professional use only.
• Please also mind the product safety information!

3. Mounting instruction

Take off the bolts, washers from all parts before assembling.
• Before first operating the press, it is necessary to unpack, mount feet, the table and the pressure gauge. These operations can be performed
in different positions, but never forget that this is the heavy elements that require the assistance of others or the use of mechanical means.
• The feet are fixed to the chassis using the screws provided, and the tables to the two B axes of Fig.02 which have previously been positioned
on the outlets of the columns according to the chosen work height Fig.02. Attach the base section and support to left and right connecting plate
using bolt ,washer, lock washer and nut.
• Move the pump assy, Fig.07 ( WP75P ), Fig.09 ( WP100P ),to the outside of the post, use bolt and washer which dismantled just now to twist
tight on the right connecting plate .
• Positioning of the Manometer: The manometer should be positioned on the hydraulic unit, which is located on the upper part of the press
Fig.06.Remove the metal cover, position the manometer, making sure that the O-ring seal which is inside the manometer casing remains at the
bottom upon installation.
• Assemble oil hose :Fig.08 ( WP75P ), Fig.10 ,Fig.11 ( WP100P ).
• During moving the machine, please make sure to use the proper lifting equipment and follow the instructions as shows Fig.02.
Caution
Working area of 1 m must be kept free both in front of and behind the machine while it is in operation so that it is always
easily accessible.
Purge air from the hydraulic system:
• Open the release valve, by turning it in an anti-clockwise direction, and open air bleed vavle, Fig.07.
• Then pump the hydraulic unit several times. Then fully turn the release vavles in a clockwise direction. The hydraulic unit is ready for
use.
Scale: 1:1
Document Ref: 8940169914_REV: 01 _ 05-2012
4. Operation
WARNING
Before the first use, please fix the machine to the floor by anchor bole. It must be ensured that the standing surface of the
machine site is firm and horizontal, and that sufficient lighting is provided for.
WARNING
To reduce risk of injury, read and understand separately provided safety instructions and safety information reported on the
press Fig.16.
WARNING
Following use of the press, keep the piston fully retracted.
WARNING
Ensure table at proper position and lock the table by pins firmly. Place the V-block on table, Fig.02, then insert workpiece
onto the V-block.
• The V-block must be used by pair, not by piece!
• Only one person is allowed to operate the press.
4.1 Operation Instruction for WP75P
• Close the release valves, Fig.07, by turning it clockwise until it is firmly closed.
• Pump the handle/foot pedal until serrated saddle nears workpiece.
• Align workpiece and ram to ensure center loading.
• Pump the handle/foot pedal to apply load onto workpiece (please see numeration in pressure gauge).
• When work is done, stop pumping handle/foot pedal, slowly and carefully remove load from workpiece by turning the release valve
counterclockwise in small increments.(must turn with the small angle, the biggest is two circles Fig.15)
• Once ram has fully retracted, remove workpiece from table.
EN
capacity
Air Pressure
[kg]
[bar]
75000
7.5-8.5
100000
7.5-8.5
F2
R(Stroke)
[mm]
[mm]
884
250
814
300
RODCRAFT PNEUMATIC TOOLS
A
B
C
[mm]
[mm]
[mm]
1140
800
1840
1200
990
1830
M
Voil
Pressure of hydraulic system
[mm]
[l]
260
4.5
235
5.6
F
E
[mm]
[mm]
245
800
300
787
[MPa]
59.92
63.69

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Wp100p

Tabla de contenido