DETAILED COMPONENTS
1. Ceiling lid pipe cover
2. Pipe cover (frontal and back part)
3. Fireplace with 2 glass doors, grill and ash pan
4. Platform of the floor
5. Pot with aerosol painting for final finish
6. Envelope containing user's guide: characteristics, assembly, operating and guarantee
7. Exothermic glove and anti-scratching cloth for cleaning the plate
8. Bag with 4 plugs of 6 mm and 4 agglomerated screw of 4,5x35 to fix the ceiling
9. Bag with 2 plugs of 8mm and 2 screws M12x20 to fix the stand with fireplace and 2 screws M12x35 to level it.

TECHNICAL CHARACTERISTICS

Parameter
Maximum smokestack intake
Fire type
Fuel consumption
Mass smoke intake
Nominal efficiency
Output
Average temperature of fumes directly into the smoke outlet
CO concentration at an average of 13% O2
Fuel load (test)
Period time to test
Average smokestack intake (test)
Net Weight
Maximum fuel load
1. INSTALLATION GUIDE
ALL LOCAL, NATIONAL AND EUROPEAN STANDARDS MUST BE COMPLIED WITH WHEN
INSTALLING THE APPLIANCE (All local regulations, including those referring to national and
European standards need to be complied with when installing the appliance).
1.1. Fireplace room. The appliance contains firebricks, ash pan and a fire grate and it has 2
glass doors. All can be removed to aid transport and installation.
1.2. Smokes exit. Flue pipe is required to connect the appliance to the smokes exit. It must be
the same diameter as the fireplace throat. The minimum length of pipe is 4000 mm from the flue
to the point of discharge. Installation must comply with all regulations and the flue system of
chimney must not be shared with another appliance.
1.3. Floor. The floor must be of suitable load bearing capacity for assembly and installation.
Weak floors can be strengthened with a panel to disperse the weight over a larger area.
1.4. Insulation and safety distances. It is advisable to insulate the back of the chimney. Walls,
ceiling or floor into which the fireplace will be placed, it must not contain any combustible
material (textile, electronic, wood, glass, paper wall etc.) In this case the isolation of these
materials is obligatory (Glasswool, Class A-1, EN 13501-1)
appliance must not be less than 250 mm from the back wall and 750 mm from the sides if they
were. The same distance of 250 mm must be respected in the roof. All combustible items
(furniture, Hi-fi, DVD player, TV or carpets) must have a minimum clearance of 1000 mm from
the front of appliance.
1.5 Ventilation. Permanent ventilation is required in the room housing the appliance. You must
consider other ventilation devices (air conditioning, fans or heating) that may work
simultaneously. The air going out must be balanced with air coming in. If necessary install an
80mm diameter inlet in the room.
Value
11-13 Pa
On and Off
5,3 Kg./h
15,8 g/s
70 %
18 Kw
466º C
0,15 %
3,9 Kg
45 min
11 Pa
316 Kg
8 Kg
and the clearance for the
(1),
Página 10 de 14