1. SPECIFICATIONS
1.1

Technical specifications

Parameter
Minimum - Maximum draught
Fuel consumption
Smoke mass flow rate
Efficiency
Nominal output
Power range
Average CO concentration at 13% of O2
NOx concentration at 13% of O2
OGC concentration at 13% of O2
Particle concentration at 13% of O2
Medium draft (trial)
Net weight
Maximum authorized load (fuel)
Reload height
Logs length
Minimum flue height
Ø Flue duct
Ø Air inlet
Ø Air outlet
Safety distances
(back)
Safety distances
(sides)
Safety distances
(frontal)
Fireplace room ventilation
Electrical wiring connection
Fan airflow (unit)
Fan output (unit)
Minimum safety distance to the air outlets
Average temperature of smoke
Type of combustion
Flue liner
Fuel
Humidity fuel logs
Certification year
Certificate number

1.2 Breakdown of delivery components

(
Make sure you have all the components described below in relation to the picture on section II of the ANNEXED document)
1. Fireplace's body.
2. 12x screws (RCr 70, RCr 70A) | 20x screws (RCr 80, RCr 100) to install outlet hot air connectors and exterior air inlet.
3. Heat-resistant spray paint for touch-ups.
4. Heat-resistant glove.
5. 2x Outlet hot air connector (RCr 70, RCr 70A). 4x Outlet hot air connector (RCr 80, RCr 100)
6. 1x Inlet air connector
7. 1x Metal clamp
8. Tool for handling registers and opening door.
9. Cleaning cloth for metal painted parts
10. Fire grate.
11.
Packaging. The wooden pallet can be used as fuel or recycled. Other packaging items must be recycled or disposed of
12.
Documentation bag: output declaration, energy label, guarantee, technical sheet, and installation and operating
characteristics manual.

1.3 Diagram of the equipment's measurements

See the ANNEXED document, section I
2. REQUIREMENTS PRIOR TO INSTALLATION
ALL LOCAL STANDARDS, INCLUDING NATIONAL AND EUROPEAN REGULATIONS MUST BE COMPLIED WITH
UPON INSTALLATION OF THE EQUIPMENT.
THE INSTALLATION MUST BE PERFORMED BY A PROFESSIONAL. FAILURE TO COMPLY WITH THIS CLAUSE SHALL
EXONERATE THE MANUFACTURER FROM ANY RESPONSIBILITY.
2.1 Ground. Make sure the ground where the appliance will be placed is able to support the weight of the device. If not, you will need
a load spreading plate for the equitable distribution of the equipment's weight. In case of doubt, please consult a specialist.
2.2 Flue liner. It is mandatory to have a smoke-tight Flue liner going from the connecting point of the base to the outside in observation
of the smoke pipe diameter. The good condition and suitability of this smoke pipe must be certified by a professional and
must also observe the relevant national regulations. This flue liner must be T400 and G type should not be shared with other
devices (see Table 1.1 Technical specifications). In cases of too much draught, when the duct exceeds 7 meters in length, or the
measurement exceeds 20 Pa, the draft must be adjusted. To do this, use the second part of the baffle plate, to install it follow the
steps: "D.3" to "D.8".
2.3 Type of appliance. Combustion chamber in sealed steel treated with Senotherm 600ºC paint and coated inside vermiculite plates
and with galvanized steel convection casing. Ember grill and smoke pipe connexion piece made from cast iron. The device has an
RCr 70
11-13 Pa
1,91 kg/h
5,4 g/s
82,3%
6,9 kW
5 – 8 kW
0,094
105 mg/Nm
3
51 mg/Nm
3
3
14,7 mg/Nm
11,9 Pa
95 kg
3 kg
175 mm
330 mm
4000 mm
150 mm
100 mm
120 mm
150 mm
150 mm
1000 mm
(entry - exit)
450 cm
2
265º C
2021
1880-CPR-044-21
Model
RCr 70A
RCr 80
11-13 Pa
11-13 Pa
1,91 kg/h
2,6 kg/h
5,4 g/s
5,4 g/s
82,3%
82.3,0%
6,9 kW
9,6 kW
5 – 8 kW
7.5 – 12 kW
0,094
0,094 %
88 mg/Nm
3
105 mg/Nm
51 mg/Nm
3
51 mg/Nm
3
11,9 mg/Nm
14.7 mg/Nm
11,9 Pa
11,6 Pa
99 kg
119 kg
3 kg
175 mm
175 mm
330 mm
500 mm
4000 mm
4000 mm
150 mm
180 mm
100 mm
100 mm
120 mm
120 mm
150 mm
150 mm
150 mm
150 mm
1000 mm
1000 mm
450 cm
2
450 cm
Silicone hose 3*wire of 1.5 mm
3
135 m
/h
20 W
250 mm
265º C
265º C
INTERMITENT
NOT SHARED
NATURAL WOOD
12-20 % - two years under cover
2021
1880-CPR-044-21
1880-CPR-044-21
RCr 100
11-13 Pa
2,4 kg/h
6,6 g/s
84,4%
12.3 kW
8.5 – 14.5 kW
0,084 %
3
105 mg/Nm
3
38 mg/Nm
3
14,7 mg/Nm
11,6 Pa
140 kg
4 kg
4 kg
175 mm
500 mm
4000 mm
180 mm
100 mm
120 mm
150 mm
150 mm
1000 mm
2
450 cm
2
2
220,8ºC
2021
2021
1880-CPR-057-21
3
3
3
10