1. SPECIFICATIONS

1.1 Technical specifications

Parameter
Minimum - Maximum draught
Fuel consumption
Smoke mass flow rate
Efficiency
Nominal output
Power range
Average CO concentration at 13% of O
Average NOx concentration at 13% of O
Average OGC concentration at 13% of O
Particle concentration at 13% de O
Medium draft (trial)
Net weight
Maximum authorized load (fuel)
Reload height
Logs length
Minimum flue height
Ø Flue duct
Ø Air inlet
Ø Hot air outlet
Inner fireplace room safety distances
Inner fireplace room safety distances
Outer fireplace room safety distances
Outer fireplace room safety distances
Outer fireplace room safety distances
Fireplace room ventilation
Minimum safety distance to the air outlets
Average temperature of smoke
Type of combustion
Flue liner
Fuel
Humidity fuel logs
Certification year
Certificate number
Fireplace room ventilation

1.2 Breakdown of delivery components

(
Make sure you have all the components described below in relation to the picture on section II of the ANNEXED document)
1. Fireplace's body.
2. Heat-resistant spray paint for touch-ups.
3. Counterweights
4. Bag with 24x screws and 24x washers.
5. Cleaning cloth
6. Heat-resistant glove.
7. Tool for handling registers and opening door.
8. 4x Leveling foots.
9. Exterior air inlet kit. (Exterior air inlet connector, connector support and 2x screws)
10. 6x Hot air outlet connector
11. Documentation bag: output declaration, energy label, guarantee, technical sheet, and installation and operating
characteristics manual.

1.3 Diagram of the equipment's measurements

See the ANNEXED document, section I

2. REQUIREMENTS PRIOR TO INSTALLATION

ALL LOCAL STANDARDS, INCLUDING NATIONAL AND EUROPEAN REGULATIONS MUST BE COMPLIED WITH
UPON INSTALLATION OF THE EQUIPMENT.
THE INSTALLATION MUST BE PERFORMED BY A PROFESSIONAL. FAILURE TO COMPLY WITH THIS CLAUSE SHALL
EXONERATE THE MANUFACTURER FROM ANY RESPONSIBILITY.
2.1 Ground. Make sure the ground where the appliance will be placed is able to support the weight of the device. If not, you will need
a load spreading plate for the equitable distribution of the equipment's weight. In case of doubt, please consult a specialist.
2
2
2
2
(back)
(side)
(back)
(side)
(glass side)
(entry - exit)
(entry - exit)
19/20160-1690-1/2
G 300 LD
G 300 LD +Plus 200
G 300 LI
G 300 LI +Plus 200
3,77 kg/h
11,2 g/s
86,98 %
14,4 kW
10 – 17 kW
0,08%
35,78 mg/Nm
3
49,36 mg/Nm
3
31,15 mg/Nm
3
12 Pa
300 kg
5 kg
200 mm
400 mm
200 mm
184 ºC
12-20 % - 2 YEARS UNDER COVER
19/20166-1366-1/2
Model
11-13 Pa
3,38 kg /h
12,3 g/s
86,83 %
14,3 kW
10 – 17 kW
0,08%
51,22 mg/Nm
3
52,05 mg/Nm
3
19,76 mg/Nm
3
11 Pa
321,5 kg
5 kg
200 mm
400 mm
4000 mm
200 mm
120 mm
120 mm
20 mm
20 mm
150 mm
150 mm
1000 mm
1000 mm
450 cm
2
250 mm
173 ºC
INTERMITENT
NOT SHARED
NATURAL WOOD
2019
G 450 LD
G 450 LI
4,1 kg /h
22,45 g/s
75%
14,68 kW
10 – 17,5 kW
0,08%
106,25 mg/Nm
3
51,61 mg/Nm
3
40 mg/Nm
3
11,81 Pa
345 kg
5 kg
200 mm
550 mm
200 mm
213 ºC
19/18684-269
10