2.6. Loading and reload fuel. You must take into account the maximum authorized load of fuel,
ensuring that when the refueling it does not exceed 200 mm in height. Do not exceed the
guidelines in the technical characteristics table.
To light the fire follow these steps: place the fuel on central on the central area of the fireplace
base and open the register primary and secondary maximum and then light the fire.
(USE ONLY FOR THE ELEMENTS TO). Once this fire is lit, control its intensity through the air
controls to achieve the desired combustion (2.2.). When the fuel load has been reduced follow
the refueling section taking into account the specified data above.
Warning: Because refueling is necessary to open the gas exit slider before opening the
door.
2.7. Mechanism blockage. It is obligatory to check all working parts, especially those that could
jam after long periods of inactivity: door handle, air controls, flue connections all operate
correctly. Ensure the exterior ventilation cannot be blocked.
2.8. Cleaning and maintenance.
2.8.1. Glass cleaning. Let the fire burn out completely before cleaning. Do not allow cleaning
product to make contact with the appliance surface or the rope seal as it will cause them to
corrode.
2.8.2. Ash pan cleaning. Before removing the ash pan, allow the fire to go out completely,
taking care that the ashes do not contain hot embers; always place the ashes in a metallic
bin.
2.8.3. Interior cleaning of the chimney and flue. It is important to clean the inside of the
appliance and the flue ways thoroughly. The frequency of the cleaning will depend of the
regularity of use, and the fuel type. It is necessary to clean the chimney flue minimum of once a
year. It is essential that a qualified chimney sweep regularly checks these elements.
2.8.4. Painting. The exothermic paint lining the inside and outside the appliance supporting up
600 ° C temperature and shows a slight characteristic odor that disappears early on.
It is also possible that after some time, the paint inside the fireplace wears off due to the liquid
corrosion, fuel or other reasons. In this case, it will be necessary to wear the rusty zones off and
repaint them again.
2.9.
(Use only the spray "Rocal spray pint 600ºC BLACK – No gris antracita).
In case of a chimney fire. All flammable elements must be placed nearest at 1000 mm away
from any part of the fireplace. Special prevention must be taken when children or elderly people
are around. In case of a fire, the air sliders must be fully closed, the house evacuated and the
Fire Bridge must be called.
2.10. Operating in adverse weather. It is possible that in certain weather conditions the
fireplace may not operate correctly: smoke mislead or not enough intake. When observing these
phenomena, it is highly recommended to close all the air controls to shut down the appliance
and call the fire brigade.
2.11. Modification of the appliance. Any modification must be authorized in writing by
Manufacturas Rocal SA. It is also compulsory to use the spare pieces recommended by
Manufacturas Rocal SA.