Cardin Elettronica SLi924 Serie Manual De Instrucciones página 15

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 37
1-2 MOT motor power supply
(to change the sense of rotation invert the cables 1 and 2
3-4 ENCODER inputs Bl-Gr for the encoder signal
5-6 ENCODER inputs Gy-Yw for the encoder signal
7
LCK block signal
8
CMN common for all inputs and outputs
9-10 LC-CH2 Potential free contact for the activation of the courtesy light (separate power
supply Vmax=30 Vac/dc: Imax=1A) or the second radio channel. Selection is carried
out on the display LCD1.
11
CMN common for all inputs and outputs
12
LP 24 Vdc 25 W output for warning lights intermittent activation (50%),
12,5 W continuous activation
13
LS 24 Vdc 3 W output for an indicator light
14
CMN common for all inputs and outputs
15
24 Vdc controlled output, powering external loads
16
CMN common for all inputs and outputs
17
24 Vdc output, powering external loads
18
TA (N.O. contact) opening button input
19
TC (N.O. contact) closing button input
20
TAL (N.O. contact) limited opening button input
21
TD (N.O. contact) dynamic button input
22
CMN common for all inputs and outputs
23
TB (N.C./8.2 kΩ) stop button input (The opening of this contact interrupts the cycle
until a new movement command is given)
24
CP (N.C./8.2 kΩ) safety edge input. Opening this contact will provoke a travel direction
inversion during the closing stage and during the opening stage
25
FS (N.C./8.2 kΩ) The opening of this contact will block all movement, until the obstruction
has been removed and the pause time has elapsed, due to the safety device cutting
in, the door will then continue moving in the closing direction (only with automatic
(2)
reclosing enabled)
26
FI (N.C./8.2 kΩ) safety and control devices in input (photocells invert the travel direction
when an obstruction is detected).
Opening this contact will provoke a travel direction inversion during closure due to
the cutting in of the safety device
27
Inner conductor for radio receiver antenna (if an external antenna is fitted use a coaxial
type cable RG58 with an impedance of 50Ω)
CS 1392A
4A
DC 0449
J1
L2
F3
10
F2
4A
J2
F1
10
Collegamento motore/encoder - Connecting motor/encoder
Branchement moteur/encodeur - Anschluss der Motor/Encoder
Conexionado motor/encoder
Colore Cablaggi - Colour Code Cable
Coloration Des Câblages - Kabelfarben
Coloración Cableados
Bl
Blu
Blue
Gr
Verde
Green
Gy
Grigio
Grey
Yw
Giallo
Yellow
Wh
Bianco
White
MOT
ENCODER
LCK
Rd
Bk
Bl
Gr
Gy
Yw Wh
1
2
3
4
5
6
B1
Signal buzzer "via radio" mode
BC
Battery charger card
CSER
Serial connection (only for diagnostics)
LCD1
Display
(5)
F1
15A blade fuse
(motor power protection)
(5)
F2
4A blade fuse
(24V circuit protection)
F3
15A blade fuse
(5)
(motor protection during battery operation)
F4
4A blade fuse
(5)
(24V circuit protection during battery operation
(5)
Nota
These are automotive type blade fuses (max. voltage
(1)
(1)
(2)
(2)
(2)
F4
BC
L1
Bleu
Blau
Azul
Vert
Grün
Verde
Gris
Grau
Gris
Jaune
Gelb
Amarillo
Blanc
Weiss
Blanco
LC/CH2
7
8
9
10
11
12
13
)
58V)
28
Outer conductor for radio receiver antenna
29
CMN common for the emergency buttons
30
EMRG1 (N.A.) ingresso pulsante per manovra di emergenza 1
31
EMRG2 (N.A.) ingresso pulsante per manovra di emergenza 2
(1)
Note
The total of the 2 external device outputs must not exceed 10W.
(2)
Note
The (N.C./8.2 kΩ) selection is carried out on the LCD1 display.
ALL UNUSED NC CONTACTS MUST BE JUMPED and consequently the corre-
sponding security device tests (FI, FS) must also be deactivated.
If you want to activate the FI, FS test both the transmission and receiver parts of
the security devices must be connected to the binding post marked (CTRL24Vdc).
If the test is active there will be a 1 second delay between the command transmission
and movement of the gate/s.
Switch on the power and make sure that the indicator LEDs are indicating the fol-
lowing conditions:
- L1
Power on
- L2
Wrong battery connection
- S1
Indicator for the blocking button "TB"
- S2
Indicator for the inverting photoelectric cells "FI"
- S3
Indicator for the stop photoelectric cells "FS"
- S4
Indicator for the safety edge "CP"
- S5
Indicator for the opening button (TA)
- S6
Indicator for the closing button (TC)
- S7
Indicator for the limited opening button (TAL)
- S8
Indicator for the sequential command (TD/CH1)
(3)
Note
If this LED is "ON" invert the battery power cables immediately.
(4)
Note
These indications are "ON" if the relative security devices are inactive. Check
that the activation of the safety devices makes the corresponding indicator
lights flash. A flashing LED indicates an alarm status.
If the green power on LED "L1" doesn't light up check the condition of the fuses
and the power cable connection at the transformer primary. If one or more of the
safety LEDs "S1, S2, S3, S4" flash check the contacts of the relative security devices
and check that the unused safety device contacts have been bridged. The indications
"S5, S6, S7, S8" appear on the display when the relative command is activated, eg.
pressing the button "TA" will force "TA" to appear on the display.
B1
MM
R1
14
15
16
17
18
19
20
21
J1
Battery connection
J2
Transformer secondary protection
J3
Emergency enable jumper
MM
Transmitter code memory module
P1
Menu navigation button (
P2
Programming and confirm button (PROG./OK)
P3
Menu navigation button (
R1
Radio frequency module, 433 MHz for S449 transmitters
15
S2
S1
T B
F I
F S
C P
S4
S3
LCD1
P2
P1
MM
22
23
24
25
26
27
28
)
)
ON
(3)
OFF
(4)
ON
(4)
ON
(4)
ON
(4)
ON
OFF
OFF
OFF
OFF
CSER
3
P3
J3
1 2
1 2
3
3
Pos.1 Pos.2
Disable
J3
Enable
29
30
31

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Sli924esbSli924elbSli924edxSli924esaSli924esy

Tabla de contenido