PROGRAMMING PROCEDURE (parameter setting)
• All the functions of the electronic programmer can be set in the Display menu "LCD1" using the three buttons contained therein:
- use the arrows to navigate through the menu and/or to adjust the display contrast;
- use "PROG/OK" to modify the parameter settings and/or to confirm.
T B
F I
PROGRAM
F S
CP
T B
F I
00.000.001
F S
CP
FW_1.0
OPTIONS
OK
"PROG/OK" to confirm
SEQUENTIAL COM.
OPEN-SHUT/
OPEN-STOP-SHUT
"PROG/OK" to set
AUTO-RECLOSING
ON/OFF
"PROG/OK" to set
PRE-FLASHING
ON/OFF
"PROG/OK" to set
WARNING LIGHTS
FIXED/
INTERMITTENT
"PROG/OK" to set
(1)
INDICATOR LIGHT
FIXED/
INTERMITTENT
"PROG/OK" to set
(2)
PHOTOCELL INVERT
DURING CLOSING/
AND IN STOP
"PROG/OK" to set
(3)
TEST FI
ON/OFF
"PROG/OK" to set
(3)
TEST FS
ON/OFF
"PROG/OK" to set
Note:
INSTALLED MOTOR
1) The indicator light flashes slowly during opening, rapidly during closing; remains lit when
LEFT/RIGHT
the gate is blocked but not completely closed and is off when the gate is completely closed.
"PROG/OK" to set
2) FI Mode:
- FI also active when the gate is blocked: If the photocells are in alarm and the gate is
blocked, no movement commands will be accepted (even opening commands);
MANUAL MODE
ON/OFF
- FI active only during closing
"PROG/OK" to set
In both cases activating the FI safety device during the closing stage will force travel
direction inversion.
3) Photocell test (FI/FS)
MEMO RADIO
If you enable the security test you will have to connect both the transmitter and the
ON/OFF
receiver to the controlled load output (CTRL 24 Vdc). When the test is enabled one
"PROG/OK" to set
second will pass between receiving a command and carrying it out.
4) Current sensor settings:
LC/CH2 OUTPUT
- Level 1 = motor electrical input + 2 amps
RADIO CHANNEL/
COURTESY LIGHT
- Level 2 = motor electrical input + 2.5 amps
"PROG/OK" to set
- Level 3 = motor electrical input + 3 amps
- Level 4 = motor electrical input + 4 amps
- Level 5 = motor electrical input + 5 amps
EXIT
The programmer checks the electrical input to the motor, detecting any eventual increase
OK
in effort above the normal operating limits and intervenes as an additional safety device.
"PROG/OK" to confirm
5) Setting the distance from the closing/opening travel limit:
BACK TO OPTIONS
To increase or reduce this distance modify the parameter in steps from 0 to 9 (range
fro 0 to 6 cm ~). By default the appliance is set to level 4 and in this way the gate will
not slam against the travel limits but will stop within a centimetre of them.
SAFETY DEVICES
OK
"PROG/OK" to confirm
TB CONTACT
NC/8K2
"PROG/OK" to set
FI CONTACT
CURRENT SENSOR
NC/8K2
"PROG/OK" to set
FS CONTACT
NC/8K2
"PROG/OK" to set
CP CONTACT
NC/8K2
"PROG/OK" to set
EXIT
OK
"PROG/OK" to confirm
BACK TO SAFETY DEVICES
16
MOTION
OK
"PROG/OK" to confirm
MOTOR SELECTION
SLi924ESB 700kg
SLi924ELB 1000kg
"PROG/OK" to set
(4)
LEVELS 1...5
"PROG/OK" to set
LIMITED OPENING
1...9 meters
"PROG/OK" to set
(5)
DIST. FROM CLOSE
0...9 steps
"PROG/OK" to set
(5)
DIST. FROM OPEN
0...9 steps
"PROG/OK" to set
Press the arrows to increase or
reduce the value (max 240 seconds).
PAUSE TIME:
30
Keep the arrow keys pressed to scroll
OK
the value rapidly.
"PROG/OK" to set
Press OK to reset the parameters to the
RESET PARAMETERS
factory default settings (excluding the
number of manouvres). Press EXIT
OK
to quit without modifying the parameters
"PROG/OK" to set
EXIT
OK
"PROG/OK" to confirm
BACK TO MOTION MENU
DISPLAY
OK
"PROG/OK" to confirm
CONTRAST
OK
"PROG/OK" to set
ADJUST CONTRAST
0...63
"PROG/OK" to confirm
REAR LIGHTING
ALWAYS ON/
60 SEC./30 SEC.
"PROG/OK" to set
EXIT
OK
"PROG/OK" to confirm
BACK TO DISPLAY MENU