Kohler K-1696-NA Guia De Instalacion página 6

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Steam Outlet
17-3/4" (45.1 cm)
3/4" NPT
Pressure Relief
3. Determine the Location of the Steam Generator
IMPORTANT! The minimum required access panel is 24" (61 cm) L x 15" (38.1 cm) H. Allow for a
minimum 12" (30.5 cm) space around all sides of the steam generator.
Ensure clearance between the steam line and any surrounding surfaces.
Allow for access to the steam generator after installation.
Allow for a 12" (30.5 cm) air gap on all sides of the generator.
Allow for a drain or spill pan.
For optimum performance, install the steam generator below the level of the steam head and as
close as possible to the steam head. The steam generator should be installed within 25 ft (7.62 m) of
the steam head in a dry, well-ventilated area
4. Install the Electrical Supply
Model
Required Electrical Service
Generator Dedicated Circuit
Product Information
Weight
Size
Electrical Rating
Water Supply
Water Supply Shut-Off Valve
Steam Line
1053772-2-E
Water Inlet
11-3/4"
(29.8 cm)
Green LED
Diagnostic Light
Field Wiring
Service Box
8-3/8"
(21.3 cm)
3/4" (1.9 cm) Min
K-1696-NA
13 kW, 240 V, 80 A, 50/60 Hz
32 lbs (14.5 kg )
18" (45.7 cm) L x 12" (30.5 cm) x 13" (33 cm)
240 V, 59 A, 50/60 Hz
3/8" copper line
3/8" NPT female
1/2" copper line (1/2" NPT
thread)
Minimum required access panel is
24" (61 cm) L x 15" (38.1 cm) H.
Allow for a minimum of 12" (30.5 cm) of
space around all sides of the steam generator.
Allow for the Drain/Spill Pan.
Control
Cable Input
6
12"
(30.5 cm)
K-1713-NA
15 kW, 240 V, 90 A, 50/60 Hz
32 lbs (14.5 kg )
240 V, 68 A, 50/60 Hz
3/8" copper line
3/8" NPT female
1/2" copper line (1/2" NPT
thread)