Setting The "Delayed Closure" On The Closing Of The Door (T2) - ISEO Zero1 THESIS 2.0 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

5. SETTING THE "OPENING" AND " DELAYED CLOSURE" TIMINGS
5.1 Setting the "opening time" (T1)
To modify the opening time of the lock, present by the
manufacturer at 15 seconds, proceed as follows:
position the powered lock to be with the bolt in set
back condition with the door open (both bolt and
door in open position);
press button P1 for the desired duration, between 1
and 180 seconds (while programming, the L1 LED
will flash at 1 second intervals).
5.2
Setting the "delayed closure" at the closing of
the door (T2)
To modify the "delayed closure" at the closing of the
locking door, preset by the manufacturer at 1 second,
proceed as follows:
position the powered lock to be with the bolt in set
back condition with the door open (both bolt and
door in open condition);
press button P2 for the desired duration, between
1 and 60 seconds (while programming, the L1 LED
will pulse at 1 second intervals).
Access to the programming buttons
P1 and P2
CAUTION
In the event that the interlocking lock
is used with other devices through the
communication channel LOCKBUS,
do not set T2 at less than 1 second
for proper functioning.
GB